Laserfiche WebLink
Table 1. Sampling and Analysis <br /> Former Lodi,Chrome <br /> _ 316 N. Main Street,Lodi,CA <br /> Sample Depth Hold <br /> Sample Location Sample I.D. OW Analysis Sample'°'. <br /> Soil <br /> Adjacent to sanitary sewer discharge point SS-1 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> Adjacent to sanitaly sewer discharge point SS-1 1.0,5.0 VOCs,SVOCs 3.0 <br /> At former location of chrome strip tank SS-2 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> At former location of chrome strip tank SS-2 1.0, 5.0 VOCs,SVOCs 3.0 <br /> Between former acid salts/acid copper tanks SS-3 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> Between former acid salts/acid copper tanks SS-3 1.0,5.0 VOCs,SVOCs 3.0 <br /> Near former location of nickel bath tank SS4 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> Near former location of nickel bath tank SS4 1.0,5.0 VOCs,SVOCs 3.0 <br /> At former location of nickel strip tank SS-5 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> At former location of nickel strip tank SS-5 1.0,5.0 VOCs,SVOCs 3.0 <br /> Repair room below floor crack- SS-6 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> Repair room below floor crack SS-6 1.0,5.0 VOCs,SVOCs 3.0 <br /> Office area SS-7 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> Office area SS-7 1.0,5.0 VOCs,SVOCs 3.0 <br /> Polishing Room SS-8 1.0,5.0 CAM 17 Metals,pH 3.0 <br /> Polishing Room SS-8 1.0,5.0 VOCs, SVOCs 3.0 <br /> Exterior location away from former plating/work areas BG-1 1.0 CAM 17 Metals - <br /> Duplicates-one per ten samples collected. An equipment rinse sample will also be collected and analy7,ed if VOCs are detected in soil <br /> samples. <br /> Notes: TEPH=total extractable petroleum hydrocarbons reported as gasoline range,diesel range,and motor oil range hydrocarbons by 8015C. <br /> VOCs=volatile organic compound by 8260B.**VOC samples(encore samples)from hold depths will be analyzed within the hold time(48 hours)if field screening indicates the presence of <br /> volatiles.Encore samples will also be collected and analyzed at other intervals if obvious signs(PID measurements,odors,etc.)of volatiles are present. <br /> Metals=title 22(CAM 17 metals),filtered sample for groundwater. <br /> * Assumes native soil will be encountered at a depth of approximately one foot below grade. <br /> ** Hold samples will be collected at depths described.The samples will be analyzed if field screening indicates the presence of impact otherwise further analysis will depend on the <br /> results of the sample collected at a depth of one foot below grade. <br /> SRPD RPDDOO/07SCC-4378 SI workplansev 2 <br />