Laserfiche WebLink
November 13,2019 Lab ID : STK1956468 <br /> Live Oak Geo Environmental Customer : 3-16608 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Wet Chem <br /> Nitrate+Nitrite as N 450ONO3F MS mg/L 28.04 37.2% 5-285 <br /> (STK 1956464-00 1) MSD mg/L 28.04 37.7% 5-285 <br /> MSRPD m /L 28.04 0.9% 530.4 <br /> 450ONO3F 11/06/19:217421JDD CCB mg/L 0.084 0.2 <br /> CCV mg/L 11.22 95.4% 90-110 <br /> CCB mg/L 0.174 0.2 <br /> CCV m /L 11.22 96.2% 90-110 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> M SRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> DQO :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Page 7 of 7 <br />