My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012061
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
437
>
3500 - Local Oversight Program
>
PR0541875
>
ARCHIVED REPORTS_XR0012061
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2020 7:29:25 PM
Creation date
3/16/2020 2:28:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012061
RECORD_ID
PR0541875
PE
2960
FACILITY_ID
FA0024017
FACILITY_NAME
CHEVRON SITE 306415
STREET_NUMBER
437
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95202
APN
1392417
CURRENT_STATUS
01
SITE_LOCATION
437 E MINER AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interim Remedial Action Test Report,Former Unocal#0187,Stockton,CA <br /> August 28,2001 <br /> System Operation <br /> The system cycles ozone/air infection between eight specially designed micro-sparge points The <br /> schedule was initially set to cycle through each point 18 times per day, for nine minutes per point per <br /> cycle There is an eight minute rest period between cycles This schedule was vatted over the course of <br /> the test as part of the system evaluation process to provide more treatment to some areas <br /> The system is designed for continuous operation, other than the rest periods between cycles Generally <br /> the system has run as planned during the test However, there was some down time, generally as a result <br /> of loose wires caused by system vibration, and some instances of tubing failure <br /> Groundwater Sampling <br /> The effectiveness of the system was monitored by collecting groundwater samples from nested <br /> piezometer wells NP-1 and NP-2 Each of these contains three 1-inch diameter wells screened at three <br /> different depths Well NP-1 is near the former UST location at the southeast corner of the site, in the <br /> treatment area The medium and deep screen intervals in well NP-1 are both within the zone of influence <br /> of one or more sparge points The shallow screen interval to well NP-1 is approximately 40 feet above <br /> the level of the shallow sparge points Well NP-2 is located down gradient from the treatment area, <br /> across California Street, approximately 75 feet from the sparge points <br /> Wells NP-1 and NP-2 have been sampled as part of the ongoing quarterly groundwater tmg <br /> program since February 5, 1999 For the current test, the wells were sampled on December 8, prior <br /> to beginning operation of the system, the sampling was performed weekly for the first three months of the <br /> test and every two weeks since then Groundwater chemical analytical data through July 17, 2001 are <br /> included to this report (Table 1) All samples were analyzed for TPHg by EPA method 8015, and for <br /> benzene, toluene, ethylbenzene, and xylenes (BTEX), and MtBE by EPA method 8020 Sample results <br /> from the ongoing quarterly groundwater monitoring and sampling program were also used for system <br /> evaluation(Table 2) Sample results for on-site wells U-1, U-2,and U-3 are discussed below <br /> The horizontal and vertical distances between the wells and the sparge points, and the screened intervals <br /> are shown on Figures 5 and 6 as cross sections Graphical representations of the historical sampling <br /> results, as well as sampling during the test period are included in Appendices C and D, respectively <br /> Groundwater Sampling Results <br /> The primary constituents of concern at this site are TPHg and benzene The following discussion is based <br /> on groundwater sampling data collected over the course of the test, from December 8, 2000 through July <br /> 17, 2001 The sample results taken before the system startup were used as the baseline for evaluating <br /> treatment effectiveness Historical quarterly sampling data from wells U-1, U-2, and U-3 were also used <br /> for this evaluation Sampling results were generally positive, with significant decreases in petroleum <br /> concentrations in many areas <br /> TPHg <br /> . The most significant wells for evaluating the effectiveness of the system are wells NP-1-65 and <br /> NP-l-111 These are near the sparge points and screened at approximately the same depths In well <br /> NP-1-65, the TPHg concentrations decreased from 33,000 ppb at the test baseline to less than 2,000 ppb <br /> 24004209-1 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.