Laserfiche WebLink
STANDARD OPERATING PROCEDURE - <br /> GROUNDWATER SAMPLING <br />' Gettler-Ryan Inc. field personnel adhere to the following procedures for the collection and handling <br /> of groundwater samples prior to analysis by the analytical Iaboratory. Prior to sample collection, the <br /> type of analysis to be performed is determined. Loss prevention of volatile compounds is controlled <br />' and sample preservation for subsequent analysis is maintained. <br /> Prior to sampling, the presence or absence of free-phase hydrocarbons is determined using a NIMC <br />' flexi-dip interface probe Product thickness, if present, is measured to the nearest 0.01 foot and is <br /> noted in the field notes. In addition, static water level measurements are collected with the interface <br />' probe and are also recorded in the field notes. <br /> After water levels are collected and prior to sampling, each well is purged a minimum of three well <br />' casing volumes of water using pre-cleaned pumps (stack, suction, Grundfos), or polyvinyl chloride <br /> bailers. Temperature, pH and electrical conductivity are measured a minimum of three tunes during <br /> the purging. Purging continues until these parameters stabilize <br /> 1 <br /> Groundwater samples are collected using disposable bailers The water samples are transferred from <br /> the bailer into appropriate containers Pre-preserved containers, supplied by analytical laboratories, <br /> are used when possible When pre-preserved containers are not available, the laboratory is instructed <br /> to preserve the sample as appropriate Duplicate samples are collected for the laboratory to use in <br />' maintaizu ag quality assurance/quality control standards The samples are labeled to include the job <br /> number, sample identification, collection date and time, analysis, preservation (if any), and the sample <br /> collector's initials The water samples are placed m a cooler, maintained at 4oC for transport to the <br />' laboratory. Once collected in the field, all samples are maintained under chain of custody until <br /> delivered to the laboratory <br />' The chain of custody document includes the job number, type of preservation, if any, analysis <br /> requested, sample identification, date and time collected, and the sample collector's name The chain <br /> of custody is signed and dated (including time of transfer) by each person who receives or surrenders <br /> 1 the samples, beginning with the field personnel and ending with the laboratory personnel. <br />' A laboratory supplied trip blank accompanies each sampling set. For sampling sets greater than 20 <br /> samples, 5% trip blanks are included. The trip blank,is analyzed for some or all of the same <br /> compounds as the groundwater samples. <br /> b Unocal Corporation, the purge water and decontamination water generated during <br /> As requested y rP <br /> sampling activities is transported to Tosco - San Francisco Area Refinery, located in Rodeo, <br />' California. <br /> hNrQM31Ur.0=h49 am-IM <br />