Laserfiche WebLink
=pLillyc°Q.\ SANAOA Np <br /> Environmental Health Department <br /> COU N T Y-- <br /> - Linda Turkatte, REHS, Director <br /> Greatness grows here. Kasey Foley, REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon,REHS <br /> Jeff Carruesco, REHS, RDI <br /> Michael Kith, REHS <br /> Willy Ng,REHS <br /> Muniappa Naidu, REHS <br /> 09/10/2019 copy <br /> Samuel J & Carla R Travaille Trust <br /> 19814 N Ripon Rd. <br /> Ripon, CA 95366 <br /> RE: Well Pump Inspection <br /> Well Location: 18888 S. North Ripon Rd Permit#: WP0038006 Inspection Date: 09/10/2019 <br /> The Environmental Health Department recently conducted a water well purnp inspection at the above address <br /> and found the following issues at the time of the inspection. In order to protect the ground water supply and <br /> your water source from potential degradation, please take the associated corrective actions. <br /> ❑ Lack of or Inadequate Concrete Platform around Wellhead. <br /> (SJC Water Well Standards, Section 4.10. —Surface Seal) <br /> Corrective Action: Repair existing or install a new concrete platform around the wellhead that <br /> extends two feet in all directions from the well casing. <br /> ❑ Lack of or Inadequate Sanitary Seal at Wellhead. <br /> (SJC Ord. Code, Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑ Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards. Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. <br /> ❑ Lack of or Inadequate Backflow Prevention. <br /> (SJC Water Well Standards, Section 4.14. —Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back <br /> siphonage into a well. <br /> ❑ Sounding Tube or Air dent not Sealed. <br /> (SJC water Well Standards, Section 4.13. —Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> ❑x Lack of Pump Permit, to be Obtained by Owner or Contractor <br /> (SJC Ord. Code, Section 9-1115.3. —Well/Pump Permit Require) <br /> Corrective Action: Complete pump permit. Permit fee is $152. Submit to 1868 E. Hazelton Ave. <br /> Stockton, CA 95205. <br /> If you have any questions, contact: Kristina Saetern, Environmental Health Assistant (209) 482-2378. <br /> Please call when work is complete. <br /> MichaeKith, REHS <br /> Program Coordinator <br /> 1868 E. Hazelton Avenue ( Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />