Laserfiche WebLink
ADDITIONAL GROUNDWATER ASSESSMENT REPORT <br /> UNIVERSITY OF THE PACIFIC <br /> 1081 W MENDOCINO AVENUE, STOCKTON, CALIFORNIA <br /> Assessor's Parcel Number: 113-140-02 <br /> County of San Joaquin Site Code: R0732 <br /> INTRODUCTION <br /> Environmental Science Associates(ESA)has prepared this report to present findings of our <br /> subsurface soil and groundwater assessments at the former University of Pacific(UOP)Physical <br /> Plant, 1081 W Mendocino Avenue in Stockton,California, referred to herein as the"site" <br /> (Figure 1) Following the removal of an underground storage tank(UST) in April 2000, UOP <br /> retained ESA to complete subsequent soil and groundwater assessments to investigate <br /> concentrations of methyl tertiary-butyl ether(MTBE)detected during the UST removal Conducted <br /> in July 2000 and January 2001,these assessments included drilling and sampling 19 exploratory <br /> soil borings and obtaining shallow groundwater and soil samples from selected locations ESA has <br /> submitted to the San Joaquin County Environmental Health Division (SJCEHD)the workplans and <br /> reports listed below <br /> • Site Invests anon Work lan University of the Pacific, 1081 West Mendocino Avenue, <br /> June 8, 2000 <br /> • Subsu ace Soil and Groundwater Assessment Re ort University of the Pacific, 1081 West <br /> Mendocino Avenue, August 25, 2000 <br /> • Additional Groundwater Assessment Workplan. U�ttversity of the Pacific, 1081 West <br /> Mendocino Avenue, November 28, 2000 <br /> The first section of this report provides a site background,discusses the UST removal in April <br /> 2000, and summarizes our initial soil and groundwater assessment in July 2000 The following <br /> section presents the results of the January 2001 groundwater assessment This is followed by a <br /> discussion of the general topographic and hydrogeologic conditions, both locally and regionally <br /> Conclusions and recommendations are found at the end of this report followed by a discussion of <br /> the field sampling methodologies and presentation of our limitations Documentation of the UST <br /> removal is provided as Appendix A, Appendix B contains previous soil boring logs and Appendix _ <br /> C contains the laboratory analytical reports Appendix D provides the Checklist of required Data <br /> for No Further Action Requests at Underground Tank Sites (Appendix B of the Tri-Regional <br /> Board Staff, October 1996) <br /> Additional Groundwater Assessment Repon ESA 1 200252 <br /> March 26 2001 <br />