My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0012250
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MINER
>
545
>
3500 - Local Oversight Program
>
PR0545551
>
ARCHIVED REPORTS_XR0012250
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2020 11:20:09 PM
Creation date
3/17/2020 1:49:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012250
RECORD_ID
PR0545551
PE
3528
FACILITY_ID
FA0012578
FACILITY_NAME
CHETS AUTO
STREET_NUMBER
545
Direction
E
STREET_NAME
MINER
STREET_TYPE
AVE
City
STOCKTON
Zip
95220
CURRENT_STATUS
02
SITE_LOCATION
545 E MINER AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 1 <br /> ' Quarterly Report - Fourth Quarter 2004 <br /> CHET'S AUTOMOTIVE <br /> 545 East Miner Avenue, Stockton, California <br /> ' 1.0. INTRODUCTION <br /> At the request of Ms Kimberly Farris-Yarwood of the Estate of Chester Farris (property owner), <br /> ' Advanced GeoEnvironmental, Inc (AGE) has prepared this quarterly report for 545 East Miner <br /> Avenue, Stockton, California(the site) The scope of work Included the monitoring and sampling <br /> of five ground water monitoring wells,submittal of monitoring and analytical data to the State Water <br /> ' Resources Control Board's GeoTracker information management system, and preparation of this <br /> report The site and its surroundings are illustrated on Figure 1 Structures,probe boring,soil sample, <br /> and monitoring well locations are shown on Figure 2 <br /> This report was prepared in accordance with Central Valley Regional Water Quality Control Board <br /> ' (CVRWQCB)guidelines for the investigation of underground storage tank(UST)sites Site history <br /> and findings from previous site investigations are summarized in Appendix A,the results of previous <br /> monitoring events are included in the tables of this report <br /> 2.0. PROCEDURES <br /> • This investigation was conducted in accordance with guidelines established by the CVRWQCB and <br /> the San Joaquin County Environmental Health Department(EHD)for the subsurface investigation <br /> ' of UST sites and sampling of ground water monitoring wells,respectively <br /> ' 2 1 WELL MONITORING AND EVACUATION <br /> On 30 November 2004,a Solmst water level meter was used to measure the depth to ground water <br /> ' in monitoring wells MW-1 through MW-5 relative to the tops of the well casings After ground water <br /> depth measurements were collected, monitoring wells MW-1 through MW-5 were purged of <br /> standing water using dedicated, disposable plastic bailers Approximately 125 and 19 gallons of <br /> twater were purged from wells MW-2 and MW-5, respectively Wells MW-1, MW-3, and MW-4 <br /> were purged dry after 0 5 to 1 gallon of ground water had been evacuated Ground water temperature, <br /> ' pH, and conductivity were measured at regular intervals during purging using an Oakton water <br /> analyzer Field data logs are included in Appendix B <br /> 22 GROUND WATER SAMPLE COLLECTION <br /> ' Ground water samples were collected from the monitoring wells using dedicated,disposable plastic <br /> bailers after allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume <br /> iImmediately upon retrieval,samples were transferred into chilled,40-milliliter(ml)EPA-approved <br /> ' Advanced GeoEnwonmentai,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.