Laserfiche WebLink
18 June 2001 <br /> AGE-NC Project No. 98-0432 <br /> tPage 4 of 6 <br /> 2.3. EXTRACTED GROUND WATER ANALYTICAL RESULTS <br /> The results of the laboratory analysis for the grab ground water samples collected at 240 minutes, <br /> 480 minutes and 720 minutes are as follows and are shown on Table 3: <br /> The grab ground water sample collected at 240 minutes had TPH-g at 100 micrograms per liter,(µg/1) <br /> tand TPH-d at 67µg/1. BTEX compounds were detected at concentrations of 0.9 4g11, 7.3 µg/l, 2.7 <br /> µg/1 and 14 ,ug/l, respectively. MTBE was detected at a concentration of 1,700,ug/l by EPA Method <br /> 8020 and at a concentration of 1,500,ug/l by EPA Method 8260. <br /> The grab ground water sample collected at 480 minutes had 89µg/1 TPH-g.BTEX compounds were ' <br />' detected at concentrations of 0.69 µg/1, 5.5 µg/1, 2'.0 4g/l and 11 Mg/l, respectively. MTBE was detected at a concentration of 1,900 4g11 by EPA Method 8020 and at a concentration of 1,700µg/l <br /> by EPA Method 8260. <br /> The grab ground water sample collected at 720 minutes had TPH-g at 95 ,ug/l. BTEX compounds <br /> .were detected at concentrations of 0.56,ue,4.4µg/1, 1.8µg/l and 4.8 /iig/l, respectively. MTBE was <br /> detected at a concentration of 1,900 ug/l by EPA Method 8020 and at a concentration of 1,600�Zg/l <br /> by'EPA Method 8260. <br />' The analytical results of water samples are summarized in Table 3. The laboratory reports <br /> (McCampbell Analytical Inc. Lab I.D. 68335 to 68337), Quality Assurance and Quality Control data <br /> and chain-of-custody forms are presented in Appendix D. <br /> 3.4. PURGED GROUND WATER DISPOSAL <br />' <br /> .. On 13 June 2001, the ground water extracted during the pumping tests was pumped from the <br /> aboveground storage Baker tank into a vacuum truck(supplied by American Valley Waste Oil); the <br /> ' purged water was transported off-site under hazardous waste manifest to Industrial Service Oil Co. <br /> Inc., a waste treatment facility located in Los Angeles, California. Documentation and uniform <br /> hazardous waste manifest for disposal of the pump test purged water is contained in Appendix E. <br /> Advanced GeoEnvironmental,Inc. <br />