Laserfiche WebLink
28 March 1997 <br /> - AGE-NC-95-0103 <br /> Page b of-6 <br /> - <br /> 52 - RECOMMENDATIONS W - <br /> T Based upon data collected at the site, AGE has the following recommendations = - <br /> A soil vapor extraction/thermal oxidizer remediation system, supplied by the Underground <br /> Storage Tank Cleanup-Fund has been delivered to the site Setup and operation of the , <br /> -' extraction system, combined with an in-situ air sparging system, should begin as soon as , <br /> _ possible <br /> The extent of impacted ground water is not defined toward the northwest(down-gradient) _ <br /> We recommend the installation of an additional monitoring well down-gradient of MW-3 <br /> • Quatterly ground water monitoring should continue The next monitoring event will be <br /> i scheduled for April 1997 <br /> 60 LIMITATIONS - <br /> MOur professional services were peiformed using that degree of care and skill ordinarily exercised by <br /> - - - - environmental consultants practicing,in this or similar localities The findings were based upon <br /> - _ - analytical results provided by_an independent laboratory Evaluations of the geologic/hydrogeologic <br /> conditions at the site for.the purpose of this investigation are made from review of reports prepared <br /> by previous consultants and a limited number of available data points (e g , monitoring wells) and <br /> T . subsurface conditions-may vary_away from these data points No other warranty, expressed or <br /> implied, is made as to=thc professional recommendations contained in this report <br /> } r _ <br />