Laserfiche WebLink
Client Number 020503879 <br /> Protect Manteca <br /> Work Order Number <br /> 03-05-0259 <br /> Table 1(continued) <br /> ANALYTICAL RESULTS <br /> Aromatic Volatile Organics and <br /> Total Petroleum Hydrocarbons as Gasoline in Water <br /> EPA Methods 5030, 8020, and Modified 8015a <br /> GTEL Sample Number 09 10 11 12 <br /> Client Identification 6 7 RINSATE MW5 <br /> MW5 <br /> Date Sampled 05/14/93 05/14/93 05/14/93 05/14/93 <br /> Date Analyzed 05/27/93 05/27/93 05/26/93 05/27/93 <br /> Detection } <br /> Analyte Limit, ug/L Concentration, ug/L <br /> Benzene 03 <03 14 <03 380 <br /> Toluene 03 <03 6 <03 15 - <br /> Ethylbenzene 03 <03 <03 <03 770 <br /> Xylene, total 05 <05 110 <05 1300 <br /> BTEX,total -- -- 130 -- 2500 <br /> TPH as Gasoline 1 10 <10 700 <10 17000 <br /> Detection Limit Multiplier 1 1 1 10 <br /> -1 <br /> BFB surrogate, % recovery 120 120 1 118 128 <br /> a Test Methods for Evaluating Solid Waste,SW-846,Third Edition,Revision 0,US EPA November 1986 Modification for TPH as <br /> gasoline as per California State Water Resources Control Board LUFT Manual protocols,May 1988 revision Bromofiuoroben- <br /> zene surrogate recovery acceptability limits are 70-130% <br /> L <br /> r' <br /> A <br /> i <br /> I <br /> } <br /> GTEL Concord,CA �_. <br /> 03050259 BTE GTEL <br /> i <br /> R <br /> t� LA90RATORIES INC <br />