Laserfiche WebLink
r 1 <br /> ` f <br /> 1 2 2 Preliminary Investigation and Evaluation <br /> On October 12, 1999, Ramage Environmental published Preliminary Investigation and Evaluation <br /> Report, which documented the results of soil and groundwater-grab samples collected from five <br /> (5) Geoprobe® soil borings (Figure 2) One boring (SB-1) drilled through the northern end of the <br /> former UST excavation was continuously cored to a depth of 43 feet <br /> The highest concentrations of diesel and gasoline hydrocarbons in soil were detected in samples <br /> collected from SB-1, located within the former UST excavation In the sample collected at 18 feet <br /> bgs from SB-1, Total Petroleum Hydrocarbons (TPH)-as-diesel was detected at a maximum <br /> concentration of 18,000 milligrams per kilogram (mg/kg), and TPH-as-gasoline was detected at <br /> 1,900 mg/kg Vertically, the extent of impacted sod beneath the former USTs was defined to a <br /> depth of between 35 and 43 feet bgs Laterally, the vertical extent of impacted sod appeared to <br /> be concentrated between 15 and 25 feet bgs, within the capillary fringe and zone of groundwater <br /> table fluctuation Total lead was not detected in the sod sample analyzed <br /> Concentrations of diesel and gasoline hydrocarbons were detected in the groundwater-grab <br /> samples collected at each of the five soil boring locations The highest concentrations were <br /> detected in the groundwater-grab sample collected from SB-1, located within the former UST <br /> excavation 2,700,000 micrograms per liter (pg/l) of TPH-as-diesel, 29,000 pgll of TPH-as- <br /> gasoline, 68 pgll of benzene, 7 5 pgli of toluene, 130 pgll of ethylbenzene, 210 pgll of xylenes, <br /> and 6 5 pgll of tertiary butanol The groundwater analytical results are summarized in Table 1 <br /> 12 3 Installation of Three Monitoring_Wells <br /> On March 23, 2001, Ramage Environmental published Monitonng Well Installation Report, which <br /> documented the installation of three on-site groundwater table monitoring wells <br /> During drilling, saturated sod and groundwater were first encountered between 19 9 and 20 8 feet <br /> bgs The static depth to the groundwater table, as measured in the three groundwater monitoring <br /> wells, ranged from 18 47 to 18 56 feet bgs The resulting groundwater surface appeared as a <br /> regular plane dipping to the northwest at a gradient of approximately 0 0013 foot/foot <br /> The groundwater samples collected from all three of the groundwater monitoring wells contained <br /> detectable concentrations of petroleum hydrocarbons (Table 1) The oxygenate compounds and <br /> 1,2-dfchloroethane (1,2-DCA) were not detected in any of the groundwater samples <br /> 5 <br /> M <br />