My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005068
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
466
>
3500 - Local Oversight Program
>
PR0545571
>
ARCHIVED REPORTS_XR0005068
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2020 1:27:30 AM
Creation date
3/18/2020 3:34:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005068
RECORD_ID
PR0545571
PE
3528
FACILITY_ID
FA0003570
FACILITY_NAME
BOBS MUFFLER & RADIATOR
STREET_NUMBER
466
STREET_NAME
MOFFAT
STREET_TYPE
BLVD
City
MANTECA
Zip
95336
APN
22104019
CURRENT_STATUS
02
SITE_LOCATION
466 MOFFAT BLVD
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. Quarterly Report -.Second-Quarter 2001 <br /> BOB'S MUFFLER SHOP <br /> ' 466 Moffat Boulevard, Manteca,California <br /> ' 1.0, INTRODUCTION <br /> ' In accordance with the request of Mr. Tom Barbour of Bob's Muffler Shop, Advanced <br /> GcoEnvironmental, Inc. (AGE) has prepared this quarterly report for the.property located at 466.. <br /> Moffat Boulevard,,Manteca, California. The scope of work included quarterly ground water <br /> ' monitoring and preparation of this report. The location of the site and the immediately surrounding <br /> area are illustrated on Figure 1; structures, former UST locations and monitoring well locations are <br /> illustrated on Figure 2.Background.information is summarized in the Preliminary Sitd Assessment <br /> Work Plan dated 30 November 1998 and Prelim inarylnvestigation and Evaluation Report dated 10 , <br /> August-1999, both prepared by AGE. <br /> 2.0. PROCEDURES <br /> ' Quarterly ground water monitoring was performed on monitoring•wells MW-1 through MW-5 on <br /> 11 June 2001. The work was performed in accordance with PHS-EHD and California Regional <br /> Water Quality Control Board - Central Valley Region guidelines for sampling ground water <br /> monitoring wells and investigating underground storage tank(UST) sites. <br /> ' 2.1. . MONITORING WELL PURGE PROCEDURES <br /> On 11 June 2001, a Solinst water level meter was used to measure the depth to ground water in the <br /> five.wells relative to the tops of the well casings. Ground water elevations; flow direction and <br /> gradient were determined from this data(Table 1). <br /> 1 After recording water level measurements,disposable bailers were used to purge the monitoring well <br /> of standing water. Approximately 8 gallons of water were removed from each well (approximately <br /> 3 well casing water volumes). Ground water temperature, pH and conductivity were measured at <br /> ' 2-gallon intervals during the purge process using an ICM water analyzer. Field data,sheets are <br /> - included in Appendix A. Purged water was stored on site in labeled, 55-gallon DOT-approved <br /> ' drums. <br /> 2.2. COLLECTION OF GROUND WATER SAMPLES <br /> Water samples were collected from each purged well with disposable bailers.Each water sample was <br /> ' transferred into laboratory-supplied 40-m1 VOA vials-containing 0.5 ml 18%hydrochloric acid as <br /> Ma sample preservative. After collection, the samples were properly labeled, placed in a chilled ' <br /> ' Advanced GeoEnviro • <br /> nmental,Inc. • <br />
The URL can be used to link to this page
Your browser does not support the video tag.