My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005080
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
466
>
3500 - Local Oversight Program
>
PR0545571
>
ARCHIVED REPORTS_XR0005080
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2020 10:39:11 PM
Creation date
3/18/2020 3:55:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005080
RECORD_ID
PR0545571
PE
3528
FACILITY_ID
FA0003570
FACILITY_NAME
BOBS MUFFLER & RADIATOR
STREET_NUMBER
466
STREET_NAME
MOFFAT
STREET_TYPE
BLVD
City
MANTECA
Zip
95336
APN
22104019
CURRENT_STATUS
02
SITE_LOCATION
466 MOFFAT BLVD
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quarterly Report - Fourth Quarter 2004 <br /> BOB'S MUFFLER SHOP <br /> 466 Moffat Boulevard,Manteca, California <br /> 1.0. INTRODUCTION <br /> At the request of Mr. Tom Barbour of Bob's Muffler Shop, Advanced GeoEnvironmental, Inc. <br /> ' (AGE)has prepared this quarterly report for the property located at 466 Moffat Boulevard,Manteca, <br /> California. The scope of work included a quarterly ground water monitoring event and preparation <br /> of this report. The location of the site and the immediately surrounding area are illustrated on <br /> ' Figure 1. Structures, former underground storage tank (UST) locations, and monitoring well <br /> locations are illustrated on Figure 2. Additional site background information is provided in <br /> Appendix A. <br /> 1 ' <br /> 2.0. PROCEDURES <br /> On 21 December monitoring wells MW-1 through MW-10 were monitored and sampled. All field <br /> work was performed in accordance with guidelines issued by the California Regional Water Quality <br /> Control Board - Central Valley Region (RWQCB) for the investigation of UST sites. <br /> 2.1. WELL MONITORING AND PURGING <br /> ' A Solinst water level meter was used to measure the depth to ground water in monitoring wells <br /> MW-1 through MW-10 relative to the tops of the well casings. After the depth to ground water <br /> measurements were collected,casing water in the wells was evacuated using dedicated, disposable <br /> ' plastic bailers.Approximately 5.5 to 6.5 gallons of water were evacuated from shallow wells MW-1 <br /> through MW-5 and MW-7 through MW-10;approximately 13.5'gallons of water were removed from <br /> deep well MW-6.All purged amounts were equivalent to a minimum of three casing-water volumes <br /> per well. <br /> Temperature, pH, and conductivity of the purged water were measured at regular intervals during <br /> ' purging using an Oakton water analyzer. Purged water was temporarily stored on-site in properly <br /> labeled, Department of Transportation (DOT)-approved 55-gallon drums. The field data logs are <br /> provided in Appendix B. <br /> 2.2. COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> A water sample was collected from each purged well with a dedicated,disposable plastic bailer after <br /> allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume. Each water <br /> r sample was transferred into laboratory-supplied 40-milliliter(ml)volatile organic analysis (VOA) <br /> 1 vials containing 0.5 ml 18% hydrochloric acid solution as a sample preservative. <br /> ' 'Advanced GeoEnvironmental,Inc. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.