My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005084
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
466
>
3500 - Local Oversight Program
>
PR0545571
>
ARCHIVED REPORTS_XR0005084
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2020 1:46:50 AM
Creation date
3/18/2020 4:00:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005084
RECORD_ID
PR0545571
PE
3528
FACILITY_ID
FA0003570
FACILITY_NAME
BOBS MUFFLER & RADIATOR
STREET_NUMBER
466
STREET_NAME
MOFFAT
STREET_TYPE
BLVD
City
MANTECA
Zip
95336
APN
22104019
CURRENT_STATUS
02
SITE_LOCATION
466 MOFFAT BLVD
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. Quarterly Report Fourth Quarter 2003 <br /> BOB'S MUFFLER SHOP <br /> 466 Moffat Boulevard, Manteca, California <br /> ' 1.0. INTRODUCTION <br /> At the request of Mr. Tom Barbour of Bob's Muffler Shop,.Advanced GeoEnvironmental, Inc. <br /> (AGE)has prepared this quarterly report for the property located at 466 Moffat Boulevard,Manteca, <br /> California. The scope of work included a'quarterly groundwater monitoring event and preparation <br /> of this report. The location of the site,and the immediately surrounding area are illustrated on ' <br /> ' Figure 1. Structures,former UST locations and monitoring well locations are illustrated on Figure 2. <br /> Site background information is provided iri Appendix A. <br /> 2.4. PROCEDURES <br /> Monitoring wells MW-1 through MW-10-were monitored and sampled on I 1 December 2003. All <br /> fieldwork was performed in accordance with guidelines issued by the Central Valley Regional Water <br /> ' Quality Control Board(CVRWQCB)for the investigation of underground storage tank(UST)sites. <br /> 2.1. WELL MONITORING AND PURGING <br /> On 11 December 2003, a Solinst water level meter was used to measure the depth to ground water <br /> ' in eight wells relative to the tops of the well casings.After the depth-to-ground water measurements <br /> were collected,casing water in the wells were evacuated using dedicated,disposable plastic bailers. <br /> ' Approximately 5.5 to 5.75 gallons of water were evacuated from wells MW-1 through MW-5 and MW-7 through MW-10;approximately 12.75 gallons of water were removed from well MW-6. All <br /> ,purged amounts were equivalent to a minimum of three casing-water volumes per well. <br /> ' Temperature, pH and conductivity were measured at regular intervals during purging using an. <br /> Oakton water analyzer to monitor pH, temperature and,conductivity"of the purged water. Purged <br />' water was temporarily stored on-site in properly labeled DOT-approved 55-gallon drums.The field <br /> data logs are provided in Appendix B. <br />' 2.2. COLLECTION AND ANALYSIS OF GROUND WATER SAMPLES <br /> A water,sample was collected from each purged well with a dedicated, disposable bailer after <br />' allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume.Each water <br /> sample was transferred into laboratory-supplied 40-m1 volatile organic analysis (VOA) vials <br />' containing 0.5 ml 18%.hydrochloric acid as a sample preservative. <br />' Advanced GeoEnvironmental,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.