Laserfiche WebLink
e7 <br /> Third Quarter,2002 Quarterly Groundwater Monitoring Report <br /> Eckert Cold Storage,Manteca,California <br /> November 19,2002 <br /> Page 4 j <br /> . Table 2-Groundwater Sample Laboratory Analytical Results(September 30,2002) <br /> GASOLINE OXYGENATES/ADDITIVES <br /> B T E X TPH-G <br /> MTBE Other Gasoline Oxygenates/Additives <br /> Detection Limits: 0.5 0.5 0.5 1.0 0.05 0.5 0.5-5.0 <br /> ugil µg/1 IAgIl µg/l mg/l µg/l >tg/l <br /> Analytical Method: 8260B 8260E 8260E 8260E 8015M 82608 8260B <br /> Sample I.D. <br /> 3471A-MW i-9/30/02 1,400 6.9 220 100 11 10 <5.0-<50 <br /> 3471A-MW3-9/30/02 41 1.5 48 19 1.2 3.1 <0.5-<5.0 <br /> 3471A-MW4-9/30102 <0.5 <0.5 <0.5 <1.0 <0.05 <0.5 1,2-DCA 3.1 <br /> 3471A-MW5-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 1.2 <0.5-<5.0 <br /> 3471A-MW6-9/30102 <05 <0.5 <0.5 <1.0 <0.05 <0.5 <0.5-<5.0 <br /> 3471A-MW7-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 <0.5 <0.5-<5.0 <br /> 3471A-MW8-9/30/02 480 2.3 51 27 5.4 9.2 <2.0--<20 <br /> 3471A-DW-9/30/02 <0.5 <0.5 <0.5 <1.0 <0.05 <0.5 <0.5-<5.0 <br /> Units: Analytical: <br /> mg/l, milligrams per liter=parts per million(ppm) B,T,E,X=benzene,toluene,ethyl benzene,total xylenes <br /> . gg/L=micrograms per liter-parts per billion(ppb) TPH-G=total petroleum hydrocarbons quantified as gasoline <br /> Gasoline oxygenates/additives= methyl tertiary butyl ether(MTBE),ethanol, <br /> tertiary butanol,di-isopropyl ether(DIPE),ethyl tertiary butyl ether(ETBE), <br /> tertiary amyl methyl ether (TAME), 1,2-dibromoethane (EDB), 1,2- <br /> dichloroethane(1,2-DCA) <br /> ♦=all other oxygenates/additives were not detected at or above the laboratory <br /> reported detection limits <br /> FUTURE WORK/RECOMMENDNTIONS <br /> The SJCEHD has indicated that continued quarterly groundwater monitoring is required at the site. The <br /> next quarterly monitoring event is scheduled for December 2002. Following evaluation of the results of <br /> the additional groundwater investigation conducted on October 10 and 11, 2002 in general accordance <br /> with the Problem Assessment Work Plan (PAWP) prepared by Condor and dated May 31, 2002, Condor <br /> anticipates requesting modification of the existing quarterly groundwater monitoring program. <br /> On October 10 and 11, 2002, Condor conducted the additional groundwater investigation activities <br /> described by the PAWP at the Eckert Cold Storage facility using direct push boring methods [Cone- <br /> Penetrometer (CPT) and Hydropunch] in order to satisfy SJCEHD requirements to further investigate the <br /> lateral and vertical extent of groundwater contamination at the site. Condor supervised the installation of <br /> ten shallow direct push (hydropunch) borings and two deep direct push (CPT) boring pairs (four CPT <br /> borings total). Condor is currently preparing a Problem Assessment Report (PAR) for submittal to the <br /> SJCEHD describing the results of the groundwater investigation conducted on October 10 and 11, 2002. <br /> CONDOR <br />