Laserfiche WebLink
1 5 <br /> Eckert Cold Storage Co. <br /> 757 Moffat Blvd., Manteca CA 11/23/98 <br /> Receptor Survey Page: 5 <br /> 5.0 Conclusions <br /> ' There are several identified receptors within 2,000 feet of the subject property. None of the <br /> receptors are likely to receive contamination from the identified plume on the subject <br /> ' property due to their location relative to the plume or their inherent protection due to the <br /> construction of the facility. The distance from the plume would require a substantial amount <br /> of time and dilutions to reach the identified receptors. <br /> ' The groundwater gradient has predominantly been in the northwest direction. This direction <br /> is away from the deep well receptors. The receptors are upgradient from the plume. <br /> WIC' concludes that the residual contamination plume is not a risk to human health based <br /> on the known receptors in this study. <br /> 1 <br /> 1 6.0 Limitations <br /> The above represents our best professional opinion as to environmental conditions at this <br /> site. These opinions were derived using data at hand, and using standards of care common <br /> to the environmental consulting community in Northern California. Additional work or <br /> sampling at this site may generate data that could lead to a change of opinion regarding site <br /> ' conditions or appropriate site remediation procedures, or both. <br /> 1 Prepared by: <br /> 1 <br /> oQRQFENO <br /> SS�� <br /> 22 339 <br /> 1 A. ee DeLano, .E. Fxw.9,3D'01 <br /> California Registered Civil Engineer, # 22339 cs'l. Cnm. <br /> 9 OFCAt�F�Q <br /> 1 <br /> 1 <br /> 1 <br /> i <br /> i <br />