My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019 (14)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2200 - Hazardous Waste Program
>
PR0514115
>
COMPLIANCE INFO_PRE 2019 (14)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2020 6:30:04 PM
Creation date
3/23/2020 10:33:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0514115
PE
2249
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Rev date: 123.15 Attachment 6, LLNL Violation Tracking Spreadsheet - Hazardous Waste Generator <br /> September- October 2015 <br /> LLNL Site 300 <br /> Violation Regulation/Code Inspection Report Action <br /> Violation Description Status <br /> Report Item # Violation Class Item <br /> At south of building 875, a heavy equipment leaking oil, partially onto two drip pans and partially on the Violation acknowledged and corrected. <br /> ground, with dark oily stained ground was observed. <br /> e See above, A larger drip pan was placed under the heavy equipment. Oily residue on <br /> asphalt (ground) was cleaned LIP and disposed as hazardous waste. <br /> Refer to Attachment 7, page 23. <br /> At building 875, metal fines were observed on the floor and various equipment inside the shop. Violation acknowledged and corrected. <br /> f See above. All metal particulate generated from this operation have been, and will <br /> continue to be managed as hazardous waste. <br /> ........------- Attachment 8 - Particle Size Analysis. <br /> 303 CCR 66265.33 FAILED TO MAINTAIN ALL COMMUNICATION OR ALARM SYSTEMS, SPILL CONTROL,OR <br /> Class 11 DECONTAMINATION EQUIPMENT <br /> CCR 66265.33 Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment, The following observations were made during the inspection (a-c) <br /> All facility communications or alarm systems,fire protection equipment,spill control equipment, and <br /> decontamination equipment,where required, shall be tested and maintained as necessary to assure its Immediately begin <br /> proper operation in time of emergency, Immediately begin this practice, required practices, <br /> .......... ---—--- ................. <br /> At building 843, a damaged pallet of well pumps containing oily liquid was observed outside. Violation acknowledged and corrected. <br /> a See above. <br /> The pumps were moved to an intact pallet. Liquid in pallet and on asphalt <br /> (ground) was cleaned LIP Using DrySorb, All clean LIP waste was managed as <br /> hazardous waste. <br /> Refer to Attachment 7, page 7. <br /> At building 874,the eyewash station was blocked by a large piece of work equipment. Violation acknowledged and corrected. <br /> b See above, The equipment near the eyewash station has been moved. <br /> Refer to Attachment 7, page 20. <br /> At upper Corp Yard 875, white residue was observed in the secondary containment inside the shed. Violation acknowledged and corrected. <br /> c See above. Hazardous waste facility personnel cleaned storage unit the day of <br /> inspection. The residue was managed as hazardous waste, <br /> -Re fe I, to Attachment 7, page 25 (includes W D R#s). <br /> RECEIVED <br /> CCC 042015 <br /> ENVIRONMENTAL <br /> HEALTH DEPARTMENT <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.