Laserfiche WebLink
A EUCA <br /> Q � <br /> . oo <br /> REVISIONS <br /> o <br /> o SFS �G <br /> 0 <br /> F V, <br /> J� <br /> ® PANDA RESTAURANT GROUP INC. <br /> 1683 Walnut Grove Ave. <br /> E Rosemead, California <br /> ° 91770 <br /> Telephone:626,799.9898 <br /> NFacsimile: 626.372.8288 <br /> r ° All ideas,designs,arrangement and plans indicated or <br /> U U represented by this drawing are the property of Panda <br /> P HOOD LI5H1l`S 00 Express Inc,and were created for use on this specific project. <br /> 2 <br /> BULBS BY OTHERS None of these ideas,designs,arrangements or plans may be <br /> I _ used by or disclosed to any person,firm,or corporation <br /> without the written permission of Panda Express Inc. <br /> ANSUL SU1n4-Y <br /> LINE TIO HOOD r- <br /> _ — e <br /> ANSUL DETECTION I d REVISIONS: <br /> LIME TO <br /> 1 <br /> HL81D I B _ _ T FACTORY 1 UREE <br /> S <br /> 1I11100 o <br /> LL <br /> \� 1 w <br /> J TEMPERATURE SEMS • • _ <br /> REMOVABLE S/S I T I FACTIY INSTALLED • • I� 'f R ` z <br /> SERVICE DCCR 24' _ • • 8Y �+ <br /> • • ,► `" 0 co <br /> CEM RELEASE/ •�!'• _�'�E y ISSUE DATE: <br /> BRACKET ASSEMBLY • • R�r Q <br /> '� • • ® v 82.18.19 ISSUED FOR PERMIT <br /> SIZES VARY �TICIV 12 1 <br /> RC[Jlvl TEMM�ERATURE SENsoR � �Q .7 <br /> PO4]TE MANUAL.PULL STATION—® INSTALLED MIN 10' FROM HOOD I � <br /> 10' MIN — 2W MApXA TH E HOOD(S) <br /> 3 <br /> 42' —48' AFF TO CENTER I <br /> 0 <br /> 0 <br /> DRAWN BY: <br /> I <br /> FUNCTIONS VARY WMI PANDA PROJECT#: D6609 <br /> 4W AFF TO CENTER <br /> ARCH PROJECT#: PRG18003 <br /> I <br /> a <br /> U <br /> MECHANICAL&PLUMBING <br /> ANSUL R-102 WET CHEMICAL GAS VALVE IDSTUDI04 <br /> ® FIRE SLIPMSSI13N SYSTEM � JOHN 1K, ENGINEER <br /> CL 1431 GREENWAY DRIVE#510 <br /> 4 FACTORY PREWIRED CONDUIT FRS! <br /> FIRE SYSTEM MICRO—SWITCH TO IRVING,TX 75038 <br /> T:972.870.1288 <br /> SUPPLY FAN SHUT—DOWN RELAY <br /> � E:JSISK@IDSTUDI04.COM <br /> PREWIRED ELECTRICAL PANEL WITH � <br /> FAN STARTERS/OVERLOADS AND RESPONSIBILITIES OF EtA MO SUPPLY FAN SHUT—DOWN RELAY. M <br /> Ln <br /> 1 . WIRE 120V FROM MAIN PANEL TO CONTROL PANEL L °' <br /> a <br /> 2. WIRE LIGHT FIXTURES BETWEEN HOOD(S) & BACK TO CONTROL PANEL x v <br /> LJ <br /> 3. WIRE TEMPERATURE SENSOR(S) FROM EXHAUST COLLARS TO CONTROL PANEL d Z FOR INFORMATION ONLY <br /> � o <br /> 4. MOUNT & WIRE ROOM SENSOR TO CONTROL PANEL <br /> 5. WIRE FAN POWER FROM MAIN PANEL THROUGH CONTROL PANEL TO FANS a W <br /> 6. WIRE SHUNT COIL TO CONTROL PANEL DATE; 90/31/2018 <br /> DWG.#: <br /> 7. WIRE GAS VALVE (IF APPLICABLE) TO CONTROL PANEL (120V FROM CONTROL PANEL) 3601878 PANDA EXPRESS <br /> DRAWN AHJ-86 <br /> WARM &WELCOME V3 <br /> ADDITIONAL RESPONSIBILITIES IF APPLICABLE SCALE. 1422 WEST COLONY ROAD <br /> 3/4" = 1'-0" RIPON, CALIFORNIA 95366 <br /> * ON ELECTRICAL WIRING DIAGRAMS* 1 • IF MULTIPLE FIRE SYSTEMS ON SINGLE CONTROL PANEL, THE FOLLOWING MUST OCCUR MASTER DRAWING <br /> TERMINAL BLOCK WIRING DETAILS CAN BE FOUND A. ANSUL AUTOMAN MICROSWITCHES TO BE WIRED IN SERIES BACK TO CONTROL PANEL <br /> B. ANSUL CATRIDGE MICROSWITCHES TO BE WIRED IN SERIES BACK TO CONTROL PANEL <br /> RESPONSIBILITIES OF ALARM CONTRACTOR SHEET NO. <br /> 1 . WIRE ANSUL ALARM MICROSWITCH TO BUILDING ALARM PANEL 2 <br /> M �40 1 . <br /> HOOD DETAIL PLAN <br /> WARM & WELCOME V3 <br />