My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
4040
>
2900 - Site Mitigation Program
>
PR0545496
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2020 3:26:09 PM
Creation date
3/24/2020 3:13:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0545496
PE
2957
FACILITY_ID
FA0003564
FACILITY_NAME
BLUE STAR
STREET_NUMBER
4040
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15727503
CURRENT_STATUS
02
SITE_LOCATION
4040 E MAIN ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
272
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
residual vacuum in the SUMMA®canister of less than 10 inches HP which APPENDIX E <br /> corresponded to a sample volume of about 0.6 Lin a 1-L SUMMA canister(i.e.,two <br /> aliquots of sample would be required).For a low-flow probe the volume of soil gas NAPHTHALENE SOIL GAS COLLECTION <br /> extracted from the formation is known from the permeability testing and from the volume <br /> expected to be collected based on the Ideal Gas Law(i.e.,0.33 L,excluding the dead <br /> volume of above ground tubing). Therefore,sample collection into canisters that do not Soil gas sampling for naphthalene is more complex than traditional soil gas investigation <br /> exceed the maximum applied vacuum(100 inches of water)can be collected if the procedures. The appropriate sample collection approach for naphthalene is USEPA <br /> sample collection time(3 minutes)is not exceeded with a calibrated flow of 100 ml/min. Method TO-17,requires the use of sorbent tubes(USEPA,1999). Soil gas <br /> investigators should select an appropriate sorbent material pursuant to the physical <br /> Additional Testing Prior to Soil Gas Sampling:Passive soil gas survey can be"a, properties of the subsurface contaminant along with the appropriate applied vacuum, <br /> performed to determine whether active soil gas samples are required at specific'; sampling flow rate,and sampling volume. Soil gas workplans should describe how the <br /> location(s)or throughout the site with low-permeability soil. The passive soil gas field investigation will meet all the requirements within this advisory as weil as those <br /> sampling method is described in Appendix A. Other guidance documents recommend noted in Method TO-17. <br /> passive sampling method in low-permeability soil for site characterization purpose <br /> (USEPA 2008,Page 13). rh Both passive and active soil gas samples may need to be collected in order to provide <br /> multiple lines of evidence to evaluate vapor intrusion exposure to naphthalene. <br /> The trademarks and brand names mentioned in this appendix is not an endorsement of Quantification of the contaminant source term is critical for risk-based decision making. <br /> a specific product but is provided as an example to the reader as a reference to what Repetitive soil gas sampling from permanent points may be warranted as soil gas grab <br /> instrument or material was successfully used in the past. Other products,which meet samples approach risk-based concentrations. Long-term monitoring may be needed,in <br /> the similar standards and quality as the above mention products may be acceptable. a fashion similar to groundwater,to ascertain representative subsurface concentrations <br /> and to document contaminant plume stability. <br /> References: 1 <br /> Sampling System Materials <br /> API,2005:American Petroleum Institute.Collecting and interpreting soil-gas samples <br /> from the vadose zone:A practical strategy for assessing the subsurface vapor-to-indoor Sorbent/Method TO-17 is recommended for confirmation sampling and analysis for <br /> air migration pathway at petroleum hydrocarbon sites. Publication#4741.Washington, naphthalene in soil gas at probe locations where this chemical was previously detected <br /> D.C.:API. by another soil gas method such as EPA Methods 5030/8260B or TO-15 or in the soil <br /> Johnson,P.C.,M.W.Kemblowski,and J.D.Colthart. 1990. Quantitative Analysis for matrix samples. Naphthalene analysis by EPA MethodTO-15 presents several <br /> the Cleanup of Hydrocarbon-Contaminated Soils by In-situ Soil Venting. Ground Water, challenges,such as contaminant carryover and variability in recovery(Hayes et al., <br /> 28(3):413-429. 2005). EPA Method TO-15 defines target analytes as having a vapor pressure greater <br /> than 0.1 mm Hg at 25°C at 1 atmosphere,and is suitable for organic compounds with <br /> McAlary,T.A.,P.Nicholson,H.Groenevelt,D.Bertrand.2009."A Case Study of Soil- carbon content ranging from C3 to C10. However,naphthalene with vapor pressure of <br /> Gas Sampling in Silt and Clay-Rich(Low-Permeability)Soils",Ground Water Monitoring 0.087 mmHg falls just below this threshold for TO-15. USEPA Method TO-17 allows <br /> &Remediation,29, No.1,Winter 2009,pp.144. greater flexibility in targeting lower vapor pressure compounds,and hydrophobic <br /> sorbents,such as Tenax TA or GR which traps organic compounds ranging from C7 to <br /> USEPA,2008:United State Environmental Protection Agency,Brownfields Technology C20 have been demonstrated to perform well when sampling heavier molecular weight <br /> Primer Vapor Intrusion Considerations for Development.EPA 542-R-08-001. VOCs(or SVOCs)such as naphthalene(Fortune,A.et al,2008). Data from samples <br /> htto://www.brownfiieldstsc.orci collected in sorbent and analyzed using TO-17 for naphthalene are reliable,provided <br /> that the requisite volume of soil gas passes through the sorbent tube. A maximum <br /> applied vacuum of 100 inches of water or less with an appropriate flow rate(e.g., s 50 <br /> ml/min)derived from the soil gas permeability testing(McAlary,T.et al,2009)should <br /> allow the sampler to collect the requisite soil gas volume. <br /> Some stationary laboratories are capable of obtaining data of acceptable quality using <br /> SUMMA®/EPA Method TO-15. If EPA Method TO-15 is used for sampling and analysis <br /> 12/10/2009 -63- 12/10/2009 -64- <br />