Laserfiche WebLink
Veeder-Root Page 2 of 3 <br /> Standard Models <br /> Console Form Number: 848290-022 <br /> Description: TLS-350 Plus Monitoring Console with integral printer (includes <br /> printer communications module) <br /> Console Form Number: 848290-002 <br /> Description: TLS-350 Plus Monitoring Console without integral printer <br /> Console Form Number: 848291-021 <br /> Description: TLS-350 Plus PC Version without Printer or Keyboard <br /> TLS-350 Plus Interface Modules <br /> The TLS-350 Plus monitoring console contains three compartments in which <br /> individual interface modules can be installed. Interface modules may be <br /> factory-installed in the console upon Initial ordering, or ordered separately as <br /> spare modules to expand an existing system. <br /> Low-Power Compartment (Limit eight per console, unless otherwise noted) <br /> Form No. <br /> Factory Description Feature Compatibility <br /> Installed <br /> Modules <br /> Four-Input Probe Interface Module (Maximum <br /> 329356-002 three per console. Includes terminal connector Series 8473 0.1 GPH <br /> for one ground temperature thermistor for the Magnetostrictive Probe <br /> volumetric line leak detector). <br /> Series 7943 Interstitial Sensor <br /> for Fiberglass Tanks and <br /> 329358-001 Eight-Input Interstitial/Liquid Sensor Interstitial Sensor for Steel Tanks <br /> Series 7943 Piping Sump Sensor <br /> Series 7943 Hydrostatic Sensor <br /> 329357-001 Five-Input Vapor Sensor Interface Module Series 7943 Vapor Sensor <br /> 329399-001 Five-Input Groundwater Sensor Module 4SITE Series 7943 Groundwater <br /> Sensor <br /> 3299S6-001 Eight-Input Type A Sensor Interface Module 4SITE Series 7943 Solid State <br /> Discriminating Interstitial Sensor <br /> 4SITE Series 7943 Solid State <br /> 329950-001 Six-Input Type B Sensor Interface Module Dispenser Pan and Containment <br /> Sensors <br /> Series 8484 Pressurized Line <br /> 330373-001 Six-Input Pressurized Line Leak Interface Leak Detection System Requires <br /> Module (One per console) TLS-350 Plus Version 7.0 or <br /> higher software <br /> High-Power Compartment (Limit eight per console, unless otherwise noted) <br /> Form No. Factory Description Feature Compatibility <br /> Installed Modules <br /> 3293S9-001 Four-Relay output Interface <br /> Module <br /> 329360-001 Two-InputfTwo-Relay Output <br /> Interface Module <br /> 329999-001 Pump Sense Interface Module Accepts Input from up to eight pump controls <br /> Three-Output Pressurized Series 8484 Pressurized Line Leak Detection <br /> 330374-001 Line Leak Controller Interface System Requires TLS-350 Plus Version 7.0 or <br /> Module higher software <br /> Communications Compartment (Limit eight per console, unless otherwise <br /> noted) <br /> Form No. Description Feature Compatibility <br /> Factory <br /> http-://www.veeder.com/dynwnic/printable.cfm?pagelD=l 76 11/16/2002 <br />