My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MADISON
>
1319
>
2200 - Hazardous Waste Program
>
PR0537648
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2020 4:29:27 PM
Creation date
3/24/2020 4:25:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0537648
PE
2220
FACILITY_ID
FA0020104
FACILITY_NAME
A&A MUFFLER & AUTO REPAIR
STREET_NUMBER
1319
Direction
S
STREET_NAME
MADISON
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14708413
CURRENT_STATUS
01
SITE_LOCATION
1319 S MADISON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> 1OUNTY— <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A&A MUFFLER &AUTO REPAIR 1 1319 S MADISON ST, STOCKTON November 01. 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone:the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment, and if present,fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br /> information by a phone. A form is provided that can be used for this purpose. <br /> This is a minor violation. <br /> 110 CCR 66262.40(a)Failed to keep signed copy of manifests from the designated facility for three years. <br /> Copies of uniform manifests for the disposal of hazardous waste for the last three years were not found on site. <br /> Hazardous waste generators shall retain copies of all manifests signed off by the disposal facility and all receipts <br /> used in a consolidated manifesting procedure on site for three years and have them readily available for review. <br /> Immediately locate a copy of all manifests and receipts for waste oil,oily absorbent and used antifreeze/coolant for <br /> the last three years, maintain them on site, and submit copies to the EHD. <br /> This is a Class II violation. <br /> 113 HSC 25160.2(b)(3) Failed to keep copies of consolidated manifesting receipts for three years. <br /> Copies of hazardous waste disposal records for the last three years were not found on site. Hazardous waste <br /> generators shall retain copies of all manifests signed off by the disposal facility and all receipts used in a <br /> consolidated manifesting procedure on site for three years and have them readily available for review. Immediately <br /> locate a copy of all manifests and receipts for waste oil, oily absorbent and used antifreeze/coolant for the last three <br /> years, maintain them on site, and submit copies to the EHD. <br /> This is a minor violation. <br /> 605 CCR 66262.34(f)Failed to completely label containers or portable tanks of hazardous waste. <br /> The waste oil container did not have all of the labeling requirements on it. Container did have the words"hazardous <br /> waste"and the accumulation start date was not required because of the amount of waste in the container and the <br /> amount of waste produced per month. All hazardous waste containers shall be marked with the following <br /> information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition(contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. <br /> This is a repeat violation, Class ll. <br /> FAD020104 PRO537648 SCO01 11101/2017 <br /> EHD 22-01 Rev.09122116 Page 4 of 5 Small Quantity Hazardous waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.