My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013080
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
3566
>
2600 - Land Use Program
>
PA-1700258
>
SU0013080
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:20:00 AM
Creation date
3/25/2020 9:10:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013080
PE
2632
FACILITY_NAME
PA-1700258
STREET_NUMBER
3566
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95304-
APN
23906018
ENTERED_DATE
3/10/2020 12:00:00 AM
SITE_LOCATION
3566 W ELEVENTH ST
RECEIVED_DATE
3/9/2020 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
single set of construction documents . <br /> ( 2 ) A grading permit will be required for this project . Submit plans and grading calculations , <br /> including a statement of the estimated quantities of excavation and fill , prepared by a <br /> Registered Design Professional . The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code . The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code . <br /> ( 3 ) The required plans must be complete at the time of submittal for a building permit . Plans must <br /> address building design and construction , fire and life safety requirements , accessibility and <br /> show compliance with the current California codes and San Joaquin County ordinances . A <br /> complete set of plans must include fire sprinkler plans , truss design submittals , metal building <br /> shop drawings , structural plans and calculations , plumbing , electrical and mechanical drawings <br /> and energy report . <br /> ( 4 ) A soils report is required pursuant to CBC § 1803 for foundations and CBC appendix § J104 <br /> for grading . All recommendations of the Soils Report shall be incorporated into the construction <br /> drawings . <br /> ( 5 ) For each proposed new building , provide the following information on the plans : <br /> a . Description of proposed use <br /> b . Existing and proposed occupancy Groups <br /> c . Type of construction <br /> d . Sprinklers (Yes or No <br /> e . Number of stories <br /> f . Building height <br /> g . Allowable floor area <br /> h . Proposed floor area <br /> i . Occupant load based on the CBC <br /> j . Occupant load based on the CPC <br /> ( 6 ) Accessible routes shall be provided per CBC § 11 B - 206 . At least one accessible route shall be <br /> provided within the site from accessible parking spaces and accessible passenger loading <br /> zones ; public streets and sidewalks ; and public transportation stops to the accessible building <br /> or facility entrance they serve . Where more than one route is provided , all routes must be <br /> accessible . § 11 B - 206 . 2 . 1 <br /> ( 7 ) At least one accessible route shall connect accessible buildings , accessible facilities , <br /> accessible elements and accessible spaces that are on the same site . § 11 B - 206 . 2 . 2 <br /> ( 8 ) Parking spaces will be required to accommodate persons with disabilities in compliance with <br /> Chapter 11 B of the California Building Code . Note that accessible parking spaces are required <br /> for each phase of the project . These parking space ( s ) shall be located as close as possible to <br /> the primary entrance to the building . <br /> ( 9 ) Adequate sanitary facilities shall be provided for the facility , per the requirements of Chapter 4 <br /> of the California Plumbing Code . <br /> ( 10 ) Pursuant to Section 422 . 4 of the California Plumbing Code , toilet facilities shall be accessible <br /> to employees at all times , should not be more th-at than 500 feet from where employees are <br /> regularly employed and accessible by not more than one flight of stairs . The plans shall <br /> indicate the location of the toilet facilities and the travel distance from work areas . <br /> PA- 1700258 — Conditions of Approval 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.