My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
713
>
2300 - Underground Storage Tank Program
>
PR0521604
>
COMPLIANCE INFO_2009 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2020 4:31:56 PM
Creation date
3/25/2020 11:38:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2018
RECORD_ID
PR0521604
PE
2371
FACILITY_ID
FA0014678
FACILITY_NAME
NATIONAL PETROLEUM
STREET_NUMBER
713
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13905214
CURRENT_STATUS
01
SITE_LOCATION
713 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f M <br /> Software Version installed: 3.0 oY ----- `' <br /> mn Mete the followinff checklist: <br /> CVYes ❑ No* Is the audible alarm o erational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> lS Yes ❑ No* Were all sensors installed at lowest point of secondary containment ano hat <br /> not interfere with their ro er o eration? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all comui <br /> 11 N/A operational? <br /> Id Yes ❑ No* For pressurized piping systems,does the turbine automatically shut dpi g se <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disf es-",;n positive shut-down? (Check all that apply) ❑,Sump/Trench Sensors; ❑Dspenser on . <br /> i Did ou confirm ositive shut-down due to leaks and sensor failure/disconnection? 0 Yes; ❑No. <br /> ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> 111f, N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s) and operating properly? If so, at what,percent of tank capacity does the alarm trigger? <br /> �— <br /> Yes* 4 No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement arts in Section E,below. <br /> i Yes* 60 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑Water. If yes,describe causes in Section E,below. <br /> �( ❑ No* Was monitorin s stem set-up reviewed to ensure proper settings?Attach set a reports, if a licable <br /> Yes <br /> JC Yes ❑ No* Is all monitoring a ui ment o perational er manufacturer's specifications? <br /> in Section E below,describe how and when these deficiencies were or will be corrected. <br /> 1?. Comments: -- <br /> Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.