LINE LEAK LO(_:f:,'OUT SETUP <br /> I-o(-.:KOUT SCHEDULE <br /> DAILY <br /> START TIME: DISABLED <br /> STOP TIME : DISABLED <br /> PERIODIC: TEST TYPE <br /> STANDARD <br /> ANNUAL TEST FAIL <br /> ALARM D I SABLED <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED <br /> GROSS TEST FAIL <br /> ALARM DISABLED <br /> ANN TEST AVERAGING: OFF LIQUID SENSOR SETUP <br /> PER TEST AVERAGING: OFF <br /> TANK TEST NOTIFY: OFF L I :DISPENSER 5-6 <br /> TRI-STATE (SINGLE FLOAT) <br /> TNK TST SIPHON BREAK OFF CATEGORY : DISPENSER PAN <br /> DELIVERY DELAY 1 MIN <br /> PUMP THRESHOLD 10-00% L12:DISPENSER 3-4 <br /> T I-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> L. 3:DISPENSER 1-2 <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> Q 2:PREMIUM PUMP <br /> LEAK TEST METHOD TYP:2.0,,,3.OIN FIBERGLASS L 4:DISPENSER 11-12 <br /> - - - - - - -- - - - - - 2.01N DIA LEN: 140 FEET TRI-STATE (SINGLE FLOAT) <br /> TEST ON DATE : ALL TANK 3.01N DIA LEN: 0 FEET CATEGORY : DISPENSER PAN <br /> DEC 18, 2008 <br /> START TIME : DISABLED SHUTDOWN RATE: 3.0 GPH <br /> TEST RATE :0.20 GAL/'HR LOW PRESSURE SHUTOFF:NO <br /> DURATION 2 HOURS LOW PRESSURE 0 PSI L 5:DISPENSER 9-10 <br /> TRI-STATE (SINGLE FLOAT) <br /> TST EARL"! STOP:DISABLED CATEGORY : DISPENSER PAN <br /> T 2:PREMIUM <br /> LEAK TEST REPORT FORMAT DISPENSE MODE: <br /> NORMAL STANDARD <br /> SENSOR: NON-VENTED L6:DISPENSER 7-8 <br /> PRESSURE OFFSET: O-OPSI T1I-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> L 7:UNLEADED ANNULAR <br /> TPI-STATE (SINGLE FLOAT) <br /> ,-_'ATEGORY : ANNULAR SPACE <br /> PRESSURE LINE LEAK SETUP I <br /> - - - - - - - - - - - - C8:UNLEADED FILL BOX <br /> T�I-STATE (SINGLE FLOAT) <br /> Q 3:DIESEL PUMP 0,"TEGORY : OTHER SENSORS <br /> Q I :UNLEADED PUMP TYF' <br /> 'P:2.0-/3.01N FIBERGLASS <br /> TYP:2.0/3.0111 FIBERGLASS 2.OIN DIA LEN: 230 FEET <br /> 2.01N DIA LEN: 160 FEET 3.0IN DIA LEN: 0 FEET L 9:UNLEADED PUMP PIT <br /> TRI-STATE (SINGLE FLOAT) <br /> 3.01N DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH :_,LiTEGORY : STP SUMP <br /> SHUTDOWN RATE: 3.0 GPH LOW PRESSURE SHUTOFF:NO <br /> LOW PRESSURE SHUTOFF:NO LOW PRESSURE 0 PSI L.10:PREM-DIESEL ANNULAR <br /> LOW PRESSURE 0 PSI TRI-STATE (SINGLE FLOAT) <br /> T 3:DIESEL ANNULAR 2,PAC'E <br /> T 1 :UNLEADED DISPENSE MODE: <br /> DISPENSE MODE: STANDARD <br /> STANDARD SENSOR: N,'_t,J-VENTED <br /> SENSOR: NON-VENTED PPE-2-J'SURE OFFSET: O.OPSI LII :PREMIUM FILL BOX <br /> PRESSURE OFFSET: O.OPSI TRI-STATE (SINGLE FLOAT.) <br /> : OTHER SENSORS <br />