Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: Mr. Cafe' Bldg.No.: <br /> Site Address: 713 North EI Dorado Street City: Stockton Zip: 95202 <br /> Facility Contact Person: Fred Esfandiary Contact Phone No.: 408 807-9839 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 Date of Testing/Servicing: 02 /03 /05 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/sen iced: <br /> Tank ID: Gasoline-87 'rank ID: Gasoline-91 <br /> ■ In-Tank Gauging Probe. Model: Mag Probe ■ In-Tank Gauging Probe. Model: Mag Probe <br /> ■ Annular Space or Vault Sensor. Model: 794380-303 ■ Annular Space or Vault Sensor. Model: 794380-303 <br /> ■ Piping Sump/Trench Sensor(s). Model: 794380-208 ■ Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ■ Fill Sump Sensor(s). Model: 794380-208 ■ Fill Sump Sensor(s). Model: 794380-208 <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ■ Electronic Line Leak Detector. Model: o84848o-oot ■Electronic Line Leak Detector. Model: o84848o-ool <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment a and model in Section E on Pae 2). 1 ❑Other(specify equipment e and model in Section E on Pae 2). <br /> 'rank ID: Diesel Tank ID: <br /> ■ In-Tank Gauging Probe. Model: Mag Probe ❑ In-Tank Gauging Probe. Model: <br /> ■ Annular Space or Vault Sensor. Model: 794380-303 ❑Annular Space or Vault Sensor. Model: <br /> ■ Piping Sump/Trench Sensor(s). Model: 794380-208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ■ Fill Sump Sensor(s). Model: 794380-208 ❑Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ■ Electronic Line Leak Detector. Model: omm8o-oot ❑Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). 1 ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ■ Dispenser Containment Sensor(s). Model: 794380-208 ■ Dispenser Containment Sensor(s). Model: 794380-208 <br /> ■ Shear Valve(s). ■ Shear Valve(s). <br /> ❑ <br /> Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 1D: 5-6 Dispenser 1D: 7-8 <br /> ■ Dispenser Containment Sensor(s). Model: 794380-208 ■ Dispenser Containment Sensor(s). Model: 794380-208 <br /> ■ Shear Valve(s). ■ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11-12 <br /> ■ Dispenser Containment Sensor(s). Model: 794380-208 ■ Dispenser Containment Sensor(s). Model: 794380-208 <br /> ■ Shear Valve(s). ■ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apptv): Q System set-up X //Il�grm history report <br /> Technician Name(print): Phillip Klingman Signature: <br /> Certification No.: 006-05-0809 License.No.: 617238 <br /> Testing Company Name: Walton Engineering,Inc. Phone No.:( 916 ) 373-1152 <br /> Site Address: 3900 Commerce Drive,West Sacramento,CA 95691 Date of Testing/Servicing: 02 / 03 / 05 <br /> UN-036-1/4 Page 1 of 3 Rev.06/04/01 <br /> CUPA: San Joaquin County Environmental WALTON <br /> INSPECTOR: Dina Craw oaGINEERING, INC. <br /> www.unidocs.org <br />