Laserfiche WebLink
San Joaquin County DIRECTOR <br /> Donna Heran,REHS <br /> P <br /> Environmental Health Department ASSISTANT DIRECTOR <br /> .co <br /> 600 East Main Street Laurie Cotulla,RENS <br /> Stockton, California 95202-3029 PROGRAM COORDINATORS <br /> Carl Borgman,REHS <br /> Mike Huggins,REHS,RDI <br /> Website: www.sjgov.org/ehd Margaret Lagorio,REHS <br /> Phone: (209) 468-3420 Robert McClellon,REHS <br /> September 15, 2008 Fax: (209) 464-0138 Jeff KaseyaREHS,RDI <br /> Foley,REHS <br /> Elite IV Contractors, Inc. <br /> 2535 Wigwam Dr. <br /> Stockton,CA 95205 SENT VIA MAIL <br /> Re: Skymart Enterprises, 713 N. El Dorado St., Stockton CA <br /> The permit(SR0055326)for the enhanced vapor recovery phase H upgrade on the underground <br /> storage tank system(UST)at the above referenced site has been approved with the following <br /> conditions: <br /> Conditions of approval: <br /> 1. Contact the local fire department,city building department and the San Joaquin Valley <br /> Air Pollution Control District for any applicable permits. <br /> 2. Any changes shall be submitted to the San Joaquin County Environmental Health <br /> Department(EHD) for approval prior to commencing work.All new addenda supercede <br /> the previous ones. <br /> 3. All components must be certified by an independent testing organization and labeled as <br /> required by the organization. (UL,ULC,ANSI,API, ASTM,etc. See California Code of <br /> Regulations(CCR),Title 23 Chapter 16 Table B for complete list). The component must <br /> bear the appropriate mark as required by the independent testing organization. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid,current contractor's licenses issued by the <br /> Contractors State License Board(may be issued to the installation company),and <br /> b. All valid, current California UST certificates issued by the International Code <br /> Council(ICC),that are applicable to the work being performed,and <br /> c. A valid,current certificate of training from the manufacturer(s)of the <br /> component(s)being tested,repaired,or serviced; <br /> and <br /> d. Each person installing or testing any component must hold a certificate of <br /> training from the manufacturer of that component. <br /> 5. Before the alarm history is cleared,a current printout must be created and available for <br /> EHD inspection. Inspection may occur during the functionality test. <br />