My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
5708
>
3000 – Underground Injection Control Program
>
PR0522753
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:56:54 PM
Creation date
3/26/2020 1:25:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3000 – Underground Injection Control Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0522753
PE
3030
FACILITY_ID
FA0015509
FACILITY_NAME
ST FRANCIS MOTEL
STREET_NUMBER
5708
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95212
APN
08703013
CURRENT_STATUS
01
SITE_LOCATION
5708 N HWY 99
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
185
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
In early May, 2004 High Tech Enterprises was contracted by the St. Francis Motel to clear Room <br /> 108. On May 5, 2004 Mr. Edward Finucane reportedly used a pair of calibrated ambient air <br /> analyzers and other field instruments to determine if any acidic or basic residues existed in the <br /> motel room. The instruments were reportedly capable of detecting and quantifying low <br /> concentration levels(0.1 to 0.01 ppmv)of volatile solvents commonly used in the manufacture of <br /> illegal drugs. Acetone, dichloromethane, isopropanol, methanol,toluene, chloroform and 1,1,1 - <br /> trichioroethane were reportedly found to not be present. No description of the instrumentation or <br /> calibration records were provided by High Tech Enterprises. The findings of the onsite <br /> investigation by High Tech Enterprises were submitted to PHSEHD in a letter report dated May <br /> 6, 2004. A recommendation by High Tech Enterprises was made to allow the human <br /> reoccupancy of Room#108. <br /> On May 5, 2004, High Tech Enterprises had the septic tank that receives liquid waste from <br /> Room#108 opened by a local septic system contractor, Frank Junior Septic Services Inc. (Frank <br /> Jr.). After the septic tank was opened up GeoAnalytical Laboratories reportedly collected a <br /> liquid sample from the septic system on May 5, 2004. No personnel from PHSEHD were <br /> notified prior to the septic system exposure and waste water sampling event. Consequently, all <br /> work was unsupervised by PHSEHD personnel. <br /> Geoanalytical Laboratories analyzed the sample for: (1)pH using USEPA Test Method 150.1; <br /> (2) iodine using USEPA Test Method SM4500-I B; (3)Iodide using USEPA Test Method <br /> 345.1; (4)chlorides using USEPA Test Method 300.0 and(5)organic volatile compounds using <br /> USEPA Test Method 8260B. <br /> The following constituents were reported to be present from GeoAnalytical Laboratories Report <br /> #Q126-09 from the Septic Tank sample. <br /> Analyte Method Reporting Limit Analytical Result <br /> Iodide USEPA 345.1 2.0 mg/kg Below analytical detection <br /> limit <br /> Iodine USEPA SM4500-1 B 0.5 mg/kg Below analytical detection <br /> limit <br /> pH USEPA 150.1 NA 7.0 units <br /> Chloride USEPA 300.0 1.0 mg/kg 120 mg/1 <br /> Main\Environmental\St.FrancisMotel\Report\Report05252006.wpd 4 <br />
The URL can be used to link to this page