Laserfiche WebLink
Table 1 <br /> Well Construction <br /> Proposed Well Decommissioning <br /> Well Material Diameter Depth Seal Location Access <br /> SP-1 PVC 12-inch 7 ft none along Navy Drive backhoe <br /> SP-2 PVC 12-inch 7 ft none along Navy Drive backhoe <br /> SP-3 PVC 12-inch 7 ft none along Navy Drive backhoe <br /> SP-4 PVC 12-inch 7 ft none along Navy Drive backhoe <br /> SP-5 PVC 12-inch 7 ft none along Navy Drive backhoe <br /> TO/r-3 steel 8-inch loft none Time Oil backhoe <br /> TO/r-4 steel 8-inch 10 ft none Time Oil backhoe <br /> TO/r-5 PVC 8-inch 10 ft none Time Oil backhoe <br /> TO/r-8 PVC 8-inch 10 ft none Time Oil backhoe <br /> TONT-I1 PVC 8-inch 10 ft none Time Oil backhoe <br /> TO/R-2 steel 8-inch 10 ft none Time Oil rig <br /> TO/R-5 steel 8-inch 10 ft none Time Oil rig <br /> TO/R-6 steel 8-inch loft none Time Oil rig <br /> TS/T-1 PVC 6-inch 9 ft 3 ft? Tesoro backhoe <br /> TS/r-2 PVC 6-inch 9 ft 3 ft? Tesoro backhoe <br /> TS/T-4 PVC 6-inch 9 ft 3 ft? Tesoro rig <br /> TS/T-5 PVC 6-inch 9 ft 3 ft? Tesoro rig <br /> TS/T-10 PVC 6-inch 9 ft 3 ft? Tesoro rig <br /> TS/M-2 PVC 2-inch 12.5 ft 3 ft? Tesoro rig <br /> PS/MW-1 I PVC 4-inch 31 ft 3 ft W of Stork Rd rig <br /> PS/MW-12 PVC 4-inch 52 ft 37 ft E of Stork Rd rig <br /> PS/MW-16 PVC 2-inch 20 ft 5 ft E of Stork Rd rig <br /> UP/MW-2 PVC 2-inch 20 ft 5 ft ST Lease rig <br /> UP/MW-3 PVC 2-inch 18.5 ft 5 ft ST Lease rig <br /> Backhoe access-pull casing and grouL <br /> Rig access TO/R-2,TO/R-5,and TO/R-6-pull casing and grout <br /> Rig access PVC-cased wells-drill out well and grout <br /> N:VCLSOC42\D0126VJ42897M Lxls Revision 0: 5/7197 <br />