Analysis Report <br /> Lancaster Laboratories Page 2 of 2 <br /> Wherequality r<s a science <br /> Quality Control Summary <br /> Client Name- ChevronTexaco Group Number 816685 <br /> Reported 08/08/02 at 07 58 PM <br /> Surrogate Quality Control <br /> Limits S7-146 <br /> Analysis Name BTE% + oxygenates by 8260B <br /> Batch number P022112AB <br /> Dibromofluoromethane 1,2-Di chloroethane-d4 Toluene-ds 4-Bromofluorobenzene <br /> 3865251 93 94 95 69 <br /> 3865252 93 94 94 90 <br /> Blank 93 95 95 90 <br /> LCS 92 95 96 92 <br /> MS 92 94 95 92 <br /> MSD 92 94 95 92 <br /> Limits 86-118 80-120 88-110 86-115 <br /> Analysis Name BTEX + Oxygenates by 8260B <br /> Batch number P022121AA <br /> Dzbromofluoromethane 1,2-Dichloroethane-d4 Toluene-ds 4-Bromofluorobenzene <br /> 3865253 93 94 94 89 <br /> 3865254 94 95 94 90 <br /> Blank 93 95 95 90 <br /> LCS 93 94 95 93 <br /> MS 92 94 96 92 <br /> MSD 93 95 95 92 <br /> Limits 86-118 80-120 88-110 66-115 <br /> • <br /> *-Outside of specification <br /> 41) The result for one or both determinations was less than five times the LOQ <br /> / <br /> } The background result was more than four times the spike added <br /> Lancaster Laboratories Inc <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> a Lancaster PA 17605-2425 <br /> 717 656 2300 Fax 717 656-2681 2216 Rev 9/11/00 <br />