Laserfiche WebLink
1 <br /> �OARO OF TRUSTEES Stir. JOAOUIN LOCAL HEALTH DIS. i%;T SERVING <br /> 16 Al Crow,Pres San Joaquin County <br /> Earl Pimentel,Vice Pres 1601 East Hazelton Avenue City of Manteca <br /> Tommy Joyce,Sec'y Stockton, California 95205 City of Escalon <br /> James F Culbertson City of Lodi <br /> John D Mast,M D JOGI KHANNA, M 0, M P H, DISTRICT HEALTH OFFICER City of Tracy <br /> Virginia Mathews Cary of Ripon <br /> Thomas Schubert,D V M San Joaquin County <br /> Daphne Shaw City of Stockton <br /> ' Harvey Williams,Ph D San Joaquin County <br /> December 30, 1988 <br /> John Bourdon, etal <br /> E -Z Gas MiniMart <br /> P. O. Box 6754 <br /> Modesto, CA 95355 <br /> RE: 1405 S MCHENRY; ESCALON <br /> SUBSURFACE ENVIRONMENTAL INVESTIGATION <br /> Please be advised that this office has reviewed the above referenced <br /> work plan. We have found the plan to be adequate provided the <br /> following considerations are addressed. <br /> 1: The suggested sampling intervals within the soil borings is <br /> 1 satisfactory; however, the samples obtained by utilizing field <br /> techniques should also be verified with a bottom-of-boring soil sample <br /> submitted for laboratory analysis. <br /> 2: Pursuant to telephone communication with ETS personnel <br /> December 30, 1988, the suggested slant boring ad)acent to the waste oil <br /> tank will require additional details. A minimum of two soil samples is <br /> required for each angle boring performed per tank. A cross-sectional <br /> diagram illustrating the angle of the slant boring and the placement of <br /> the two soil sampling points will be necessary prior to the issuance of <br /> ' the drilling permit. In order to obtain maximum sampling points at <br /> both ends of tanks, we recommend the slant boring be performed parallel <br /> to the tank, and the first soil sample be collected at the tank bottom <br /> interface with native soil and the second sample be collected at the <br /> j termination of the boring which is aligned with the opposite end of the <br /> tank. If this recommendation cannot be achieved at this site, then <br /> illustrate the best possible angle and sampling points. <br /> ' 3: Review of our files indicates the waste oil tank has not <br /> previously been registered nor have the appropriate tank fees been <br /> applied to this tank. Enclosed is a Fee Worksheet and a Closure Plan <br /> informational packet. Please complete the Closure Plan information and <br /> submit all the required fees at the time of submittal for the permanent <br /> closure of the waste oil tank. <br /> These issues should be addressed in a revised sampling plan which must <br /> be submitted to this office for approval prior to initiating the work <br /> plan. <br /> It should be noted that additional sampling may be necessary should the <br /> results of the sampling effort not adequately define the extent of <br /> ' Administration Clinical Services Environmental Health PubliC Health Nursing <br /> 468-3400 468-3830 468-3420 468-3860 <br /> ' Air Pollution Community Services Laboratory WIC <br /> 468-3470 468-3820 466-3460 468-3280 <br /> AIDS Inlormation 468-3820 <br />