My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0005737
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
6100
>
2900 - Site Mitigation Program
>
PR0515353
>
ARCHIVED REPORTS_XR0005737
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:32 PM
Creation date
4/1/2020 2:35:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0005737
RECORD_ID
PR0515353
PE
2950
FACILITY_ID
FA0012099
FACILITY_NAME
ARCO STATION #595
STREET_NUMBER
6100
Direction
N
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
6100 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NI k <br /> 885 Jarvis Drive <br /> Sequoia Morgan Hill CA 95037 <br /> r Analytical (468)772-9600 <br /> FAX(408)782-6308 <br /> WWW sequoialabs Corr <br /> Secor-Rancho Cordova Project ARCO#595 Stockton,CA <br /> 3017 Kilgore Rd Suite 100 Project Number ARCO 4595, Stockton,CA Reported <br /> Rancho Cordova CA,95670 Project Manager Rusty Benkosky 10/2W02 08 25 <br /> Notes and Definitions <br /> A-01 The onginal result for this analyte which was analyzed within hold time but exceeded the calibration curve was 72 ppb <br /> A-02 The original result for this analyte which was analyzed within hold time but exceeded the calibration curve was 140 ppb <br /> A-03 The ongtnal result for this analyte which was analyzed within hold time but exceeded the calibration curve was 100 ppb <br /> HC-21 Chromatogram Pattem Gasoline C6-C10 <br /> HT-04 This sample was analyzed beyond the EPA recommended holding time The results may still be useful for their intended purpose <br /> 0-09 The result was reported with a possible high bias due to the continuing calibration verification falling outside acceptance cntena <br /> QM-07 The spike recovery was outside control limits for the MS and/or MSD The batch was accepted based on acceptable LCS <br /> recovery <br /> QR-02 The RPD result exceeded the control limits,however,both percent recovenes were acceptable Sample results for the QC batch <br /> were accepted based on percent recovenes and completeness of QC data <br /> 5-02 The surrogate recovery for this sample cannot be accurately quantified due to interference from coeluting organic compounds <br /> present in the sample <br /> DET Analyte DETECTED <br /> ND Analyte NOT DETECTED at or above the reporting limit <br /> NR Not Reported <br /> dry Sample results repotted on a dry weight basis <br /> RPD Relative Percent Difference <br /> Sequoia Analytical-Morgan Hill The results in this report apply to the samples analyzed in accordance with the chain <br /> ofcuslody document This analytical report must be reproduced in its entirely <br /> 17 of 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.