Laserfiche WebLink
Table 1 <br /> Groundwater Monitoring Data and Analytical Results <br /> Former Texaco Service Station#309075 <br /> 3978 South Highway 99 <br /> Stockton,California <br /> EXPLANATIONS: <br /> TOC=Top of Casing MO=Motor Oil X=Xylenes <br /> (ft.)=Feet DRO=Diesel Range Organics MTBE=Methyl Tertiary Butyl Ether <br /> DTW=Depth to Water GRO=Gasoline Range Organics (gg/L)=Micrograms per liter <br /> GWE=Groundwater Elevation B=Benzene --=Not Measured/Not Analyzed <br /> (msl)=Mean Sea Level T=Toluene QA=Quality Assurance/Trip Blank <br /> TPH=Total Petroleum Hydrocarbons E=Ethylbenzene <br /> ANALYTICAL METHODS: - {� <br /> TPH-MO,TPH-DRO and TPH-GRO by EPA Method 8015B <br /> BTEX and MTBE by EPA Method 8260B <br /> * TOC elevations were surveyed on November 23,2009 by Muir Consulting,Inc. Vertical datum is NAVD 88 from GPS observations. <br /> TOC elevations were surveyed on July 14,2008,by Muir Consulting,Inc.Vertical datum is NAVD 88 from GPS observations. <br /> " Data collected from Quarterly Monitoring Report-Fourth Quarter 2006,dated 19 February 2007,by Advanced GeoEnvironmental,Inc.,and inserted into table by ARCADIS U.S.,Inc. <br /> ' Laboratory report indicates the sample was re-analyzed at a DFI outside the method hold time. The reanalysis results were<50 ug/L. <br /> 2 Laboratory report indicates DRO was detected in the method blank at a concentration of 33µg/L. Results from the reextraction are within the limits. The hold time had expired <br /> prior to the reextraction therefore,all results are reported from the original extract. The DRO result for the reextract is ND. <br /> 3 Laboratory report indicates DRO was detected in the method blank at a concentration of 33µg/L. Results from the reextraction are within the limits. The hold time had expired <br /> prior to the reextraction therefore,all results are reported from the original extract. The DRO result for the reextract is 220µg/L. <br /> 4 Laboratory report indicates DRO was detected in the method blank at a concentration of 33 gg/L,. Results from the reextraction are within the limits. The hold time had expired <br /> prior to the reextraction therefore,all results are reported from the original extract. Similar results were obtained in both extracts. <br /> NOTES: <br /> Table 1-Groundwater Monitoring Data and Analytical Results obtained from Gettler-Ryan Inc.,dated 06/15/10 <br /> Results dated from 09/12/08 to 06/15/10,compiled by Getter-Ryan Inc. <br /> Results dated 12/1/10 and subsequent,compiled by ARCADIS U.S.,Inc. <br />