FACILITY_NAME
HAPPY LEMON
STREET_NUMBER
6349
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09746335
CURRENT_STATUS
01
SITE_LOCATION
6349 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REV. DATE NO. <br /> PANEL 'A' VOLTAGE: 120/208Y WIRE: 4 MOUNTING: FLUSH NOTES: <br /> BUS RATING: 125A PHASE: 3 AIC RATING: 10K ELECTRICAL SCOPE OF WORK: <br /> MAIN REQ.: TYPE: CONDITION: EXISTING 1. NEW EQUIPMENT OUTLETS & CIRCUITS (USE EXISTING <br /> © w CIRCUITS WHERE POSSIBLE) <br /> ¢ 2. LIGHTING TO REMAIN AS EXISTING <br /> O CB LOAD DESCRIPTION LOAD KVA a LOAD KVA LOAD DESCRIPTION CB p Y <br /> 0 <br /> P T P T <br /> 1 K 2 50 DISPENSER, HOT WATER 4.0 A 0.2 (E) LIGHTS - EMERGENCY 1 20 D 2 <br /> 3 K DISPENSER, HOT WATER 4.0 B 0.3 LIGHTS - OVERHEAD DINING 1 20 C 4 <br /> 5 20 SPARE C 0.4 LIGHTS - OVERHEAD KITCHEN/BACK 1 20 C 6 <br /> 7 G 1 1 20 LIGHTS/FAN - RESTROOM 0.3 A 0.4 REC. - WINDOWS (SIGN) 1 20 D 8 al:l"ss1 <br /> 9 D 1 20 (E)ALARM SYSTEM 0.2 B 1.1 REC. - FRONT 1 20 G 10 o QR oti�� <br /> e-o�o <br /> C <br /> 11 K 1 20 REFRIGERATOR, SANDWICH/SALAD PREP 1.0 1.1 REC. - SERVICE AREA 1 20 G 12 � . C, m <br /> 13 K 1 20 REFRIGERATOR, UNDERCOUNTER, COMPACT 0.5 A 1.1 REC. - BACK/STORAGE/W.C. 1 20 G 14 E L E C T R I C A L S C H E D U L E C-17,591 <br /> D 16 Exp.06-30-19 <br /> . <br /> K 1 20 BLENDER, BEVERAGE x 2 2.8 B 02 REC - POS 1 20 N <br /> 15 n .� <br /> 17 K 1 20 DISPENSER, BEVERAGE/NON--CARBONATED 1.4 C 1 .4 FREEZER, REACH-IN 1 20 K 18 F civ % 04`' <br /> OF CALIF <br /> 9 K 1 20 STEAMER, BEVERAGE 1.3 A 1 .1 REFRIGERATOR, REACH-IN 1 20 K 20 Q <br /> 21 K 2 20 INDUCTION HOT PLATE 0.9 B 1.3 !CE MAKER 2 20 K 22 NoIteQty Equipment Cafe or Manufacturer E � a- o ..° .� � w p <br /> 23 K INDUCTION HOT PLATE 0.9 C 1 .3 ICE MAKER K 24 Y Model Number Q y _ d p z (� <br /> 1 1 REFRIGERATOR, SANDWICH/SALAD PREP TRUE FOOD SERVICE TSSU-48-12D-2-ADA 8.6 1 .0 0.33 115 1 X 5--15P Z <br /> 25 M 50 2 7 A 1 5 M 26 2 1 REFRIGERATOR, UNDERCOUNTER, COMPAQ DELFIELD <br /> HOT WATER HEATER 2.7 B 1.5 AC-1 UNIT 3 30 M 28 UC4048 4.0 0.5 0.2 115 1 X 5-15P O5 2 BLENDER, BEVERAGE VITAMlX 4 <br /> 29 M 3 013 11 .5 2.8 2.0 120 1 X 5-•-15P � < <br /> 2.7 G 1.5 M 30 6 1 DISPENSER, BEVERAGE/NON-CARBONATED BUNN--O-MATIC 34000.0080 12.0 1.4 N <br /> 31 SPARE 1.7 M 32 4 120 1 X 5-15P O W U � <br /> 7 1 STEAMER, BEVERAGE ASTRA <br /> 33 1.7 AC-2 UNIT 3 35 M 34 sTS240o 12.0 1.30 110 1 x 5-15P }' <br /> Ca <br /> 9 2 INDUCTION HOT PLATE ADCRAFT IND-�A120V 15.0 1.80 120 1 X 5--15P <br /> 35 1 7 M 36 10 1 DISPENSER, HOT WATER BUNN-O-MATIC 0 � Y <br /> 37 28300.0001 38.6 8.0 208 1 X z � i <br /> SPARE 38 11 1 FREEZER, REACH-IN TRUE FOOD SERVICE or equal TS-72F 12.0 1 <br /> 39 40 .4 1 .0 115 1 X 5-20P 0 m ca <br /> 12 1 REFRIGERATOR, REACH-IN TRUE FOOD SERVICE or equal TS-72 9.6 1 .1 0.5 115 1 X 5-15P WCD <br /> 41 42 13.1 1 ICE MAKER HOSHIZAKI AMERICA - w `�/ <br /> DEMAND LOAD CALCULATION KM 901 MAH 11.0 2.6 208-230 1 X Z W � <br /> 19 1 HOT WATER HEATER, GAS A.O. SMITH DEN-40 38 8.0 208-230 .�-,- > <br /> DEMAND SUBTOTAL NEC DEMAND FACTOR KVA UI„ O L � <br /> (DNTINUOUS LOAD (C) 1.0 125% 1.3 CU = <br /> 9.D W = <br /> DEDICATED LOAD (D) 9.0 100% 4 Q)� <br /> GENERAL RECEPTACLE (G) 3.3 100% of 1st 10KVA&50% of remaining 3.3 LL <br /> KITCHEN EQUIPMENT (K) 21.9 65% 14.2 Q <br /> MECHANICAL EQUIPMENT (M) 9.6 125% of largest motor& 100% of remaining 10.9 V_ <br /> Q � <br /> TOTAL DEMAND KVA 38.7 O� <br /> .360 <br /> AMPS @ 1201208, 3 PHASE, 4 WIRE: 107.5 <br /> ELECTRICAL PANEL SCHEDULE & L 107.5 AMPS TOTAL LOAD - c -. _ _____.. G FI Twl M C9 <br /> OAD CALLS I <br /> 125 AMPS AVAILABLE <br /> (N) OFFICE _ 13. M CO <br /> --- <br /> 0 Lo <br /> co Lo V <br /> L- ' - �L I_ --1 w a N <br /> U O <br /> Cl <br /> CEILING U <br /> RECEPTACLE PER <br /> 42 DR d- , NEC ART.210.62 Q W C� <br /> �m � P05 <br /> 08 ! e V IW rN- N <br /> ELECTRICAL NOTES: T <br /> � cl.G Z (1 -z <br /> 6 <br /> 1. SWITCHES,CONTROLS,THERMOSTATS, ETC.,ARE TO BE INSTALLED NO HIGHER THEN 48"TO 8. ALL DOCUMENTATION REGARDING THE SERIES RATED BREAKERS TO BE USED ON THE * - 7z U J <br /> Z <br /> THE TOP OF THE BOX ABOVE FINISHED FLOOR. PROJECT WILL BE AVAILABLE FOR THE FIELD INSPECTOR UPON REQUEST, THE SERIES 1 Z J LU _Q <br /> RATED COMBINATIONS SHOULD BE HIGHLIGHTED AND TABBED FOR THE INSPECTOR'S USE. V <br /> 2. RECEPTACLE OUTLETS TO BE INSTALLED TO BE NO LOWER THEN 15"TO THE BOTTOM OF �„ m <br /> = <br /> BOX ABOVE FINISH FLOOR. 9. A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT EACH SERVICE~ ---- z v W <br /> W <br /> DISCONNECTING LOCATION IN COMPLIANCE WITH 2016 NEC ART. STORAGE <br /> 3. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC 2016 CODE. AREA I ORW <br /> 10. ALL ELECTRICAL EQUIPMENT SHALL BE FIELD MARKED WARNING QUALIFIED PERSONAL _ 2 <br /> J <br /> 4. RACEWAYS WILL COMPLY WITH 2016 NEC. OF THE POTENTIAL ARC FLASH HAZARDS AND THE APPROPRIATE PPE REQURED, PER 2016 DEDICATED 2flA SIGN CIRCUIT NEAR <br /> NEC. F- W <br /> ENTRANCE PER NEC ART,600.5 `r z <br /> 5. ALL KITCHEN APPLIANCES AND MOTORS(IN COMPLIANCE WITH NEC)TO HAVE DISCONNECT + � (W!171SCDNNECT <br /> SWITCH. I SERVICE } M <br /> 11. ALL KITCHEN APPLIANCES OF MORE THAN HP TO BE PROVIDED WITH A UNIT SWITCH 44' <br /> C <br /> 6. ALL FEEDERS AND ALL OTHER SYSTEMS(BRAND, FEEDERS, EQUIPMENT WHIPS}TO ROSS <br /> THAT COMPLIES WITH 2016 NEC. GD Gfl AREA DINING T J EVE oLANDING v U) <br /> $ AREA CLG <2/o <br /> COMPLY WITH NEC, 12. ALL ELECTRICAL WIRING TO BE IN CONDUITS,NO FLEX CABLE ALLOWED. 44" SLOPES} <br /> 7. ANY SERIES RATED EQUIPMENT TO HAVE REQUIRED SIGNAGE IN COMPLIANCE WITH 2016 I10 WASH/PREP f <br /> NEC(IDENTIFICATION OF DICONNECTING MEANS SHALL BE MARKED IN A DURABLE MANNER TO AREA <br /> INDICATE PURPOSE) a ® � <br /> J <br /> i <br /> (E}ELECT.PANEL'A' <br /> CEILING <br /> � <br /> ! � <br /> CIRCUIT, CONDUIT, & GROUNDING NOTES: CW!EXISTING A.C. RECEPTACLE PER <br /> ELECTRI _ f AL SYMBOLS 1201208W125A3PH FI NEC ART.210.62 <br /> �4 Z <br /> O <br /> FIELD VERIFY ALL EXISTING CONDITIONS (SUGGESTED LOCATIONS FOR NEW EQUIPMENT OUTLETS AND T <br /> �3 r_� �5 <br /> CONVENIENCE OUTLETS SHOWN - USE EQUIVALENT NEARBY CLO c <br /> LU.+ <br /> i r� .)� C) <br /> AIC RATINGS FOR ALL PANELS AND CIRCUIT BREAKERS TO BE PER 2010 CEC. EXISTING OUTLETS WHEN POSSIBLE) FI 3s"DR � 19 �AYM� 46 W N <br /> Z <br /> PANELS TO BE MARKED PER CEC ARTICLE 110-22 FOR SERIES RATED PANELS. 1 � = I W CN <br /> � <br /> EQUIPMENT CONDUIT TYPES:ALL EMT(NO FLEX CABLE ALLOWED). I- I El - L01 <br /> EQUIPMENT CONDUIfi IZES: 120V DEDICATED SING � <br /> SIZES:ALL 12aV USE#12 WIRE LE OUTLET (TO BE 18 ABOVE FLOOR _ GFl +44 � 1 CO) �-- d Q <br /> UNLESS OTHERWISE NOTED (E) RESTROOM L � CL. 0- U U <br /> ALL ABOVE 200V USE#11 WIRE ) aa o <br /> J I.LLZ <br /> 120V DUPLEX OUTLET (TO BE 18" OVER FLOOR UNLESS N � O � Y <br /> HALL <br /> GROUNDING NOTE: OTHERWISE NOTED) Z <br /> THE CONNECTION OF A GROUNDING ELECTRODE CONDUCTOR TO A GROUNDING ELECTRODE SHALL BE J O <br /> ACCESSIBLE AND MADE IN A MANNER THAT WILL ASSURE A PERMANENT AND EFFECTIVE GROUND. <br /> 120V QUADPLEX OUTLET FI M <br /> WHERE NECESSARY TOASSURE THIS FOR A METAL PIPING SYSTEM USED AS A GROUNDING + 0 <br /> ELECTRODE,EFFECTIVE BONDING SHALL BE PROVIDED AROUND INSULATED JOINTS AND SECTIONS � 120V CEILING MOUNTED DUPLEX OUTLET; MOUNT ABOVE SHOW ..� <br /> AND AROUND ANY EQUIPMENT THAT IS LIKELY TO BE DISCONNECTED FOR REPAIRS OR REPLACEMENT. CLG WINDOW. OUTLET & PLATE COVER SHALL MATCH CEILING, <br /> BONDING CONTRACTORS SHALL BE SUFFICIENT LENGTH TO PERMIT REMOVAL OF SUCH EQUIPMENT MOUNT PARELLEL WITH STORE FRONT. <br /> WHILE RETAINING THE INTEGRITY OF THE BOND. <br /> Q JUNCTION BOX <br /> ♦ TELEPHONE OUTLET, FLUSH MOUNTED IN WALL +36" (VON) <br /> On GROUND FAULT INTERRUPTED OUTLET (ALL KITCHEN OUTLETS) ELECTRICAL OUTLET PLAN <br /> 0 SPECIAL OUTLET (SEE NEMA) <br /> Oc TIME CLOCK (ASTRIONOMICAL) - FOR WINDOW SIGNAGE ONLY SCALE: 1/4" = 1'-0" <br /> Date: 5116118 <br /> Drawn: GCC <br /> Sheet: <br /> E-1 <br />