Laserfiche WebLink
Ao <br />o <br />fhrislR RESTROOM <br />4 "' 1' RESTROOM <br />o� <br />�o <br />ZU <br />N U <br />o� <br />z:i <br />i? Z0 <br />o <br />co <br />u a� <br />CV U <br />u <br />130 <br />� o <br />=z� <br />u <br />b" <br />CENTERLINE OF <br />COLUMN <br />14 6_ <br />------ ------- t:! <br />I <br />I 45 <br />I <br />25-3 7/8" 1 6'-2 1/4" <br />CENTERLINE OF <br />COLUMN <br />1 <br />13'-1" <br />4'-4., <br />V-6`` <br />CENTERLINE OF <br />I COLUMN <br />44'-7" <br />16-0" <br />2'-2" 6'-Z" <br />{ 38 <br />4 1 r- 717 10 1I I tv <br />A5.4 A5.1 I / I I RR I 6 I <br />6 <br />0 I 3 <br />0 I ?�.I r� _` i I <br />1 RESTROOM ...�. <br />SCALE: 3/9'= V-0' (TYPICAL) <br />ARESTROOM <br />4-41/2" 6'-1 1 1/2" <br />51-8" 11'4' 1. 27-7 <br />2'-6" 44'-7" <br />I <br />47--l" <br />FLOOR PLAN <br />SCALE: 1/4"= 1'-0" <br />ENLARGED RESTROOM PLAN <br />SCALE: 1/2"= V-9' <br />NORTH <br />15-6" <br />1 <br />ASA <br />tl.�o <br />23'-9" <br />FLOOR AREAS: 788 S.F. <br />mil *iii <br />FLOOR PLAN KEYNOTES: REVISIONS <br />1. DIMENSIONS ARE TO FACE OF STUDS -TYPICAL U.N.O. -SEE STRUCTURAL DRAWINGS <br />FOR FOUNDATION DIMENSIONS <br />2. 2 X 6 STUDS AT 16" OC EXTERIOR WALLS WITH BATT INSULATION ON 6" HIGH CURB - <br />FACE OF PLYWOOD SHEATHING TO ALIGN WITH FACE OF CURB - SEE DETAILS 1 <br />THROUGH 4/AD3 AND STRUCTURAL DRAWINGS FOR CURB/FOUNDATION DIMENSIONS <br />- PROVIDE 2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND <br />PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND <br />AT 10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 718.2.1 - <br />SEE STRUCTURAL DRAWINGS <br />3. 2 X 6 OR 2 X 4 STUDS (SEE LEGEND BELOW AT 16" O.C. AT INTERIOR WALLS - PROVIDE <br />2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, <br />INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT <br />INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 708.2.1 <br />4. 5 1/2" X 20 GA METAL STUDS AT 16" O.C. AT INDICATED EXTERIOR WALL <br />5. 3 5/8" X 25 GA METAL STUD 7'-0" HIGH WALL - SEE BUILDING SECTIONS SHEET ASA <br />6. STEEL COLUMN -SEE STRUCTURAL DRAWINGS <br />7. ALUMINUM STOREFRONT ASSEMBLY - TYPICAL - INSTALL PER MANUFACTURER'S <br />SPECIFICATIONS - SEE DOOR SCHEDULE AND WINDOW SCHEDULES <br />8. OPERABLE DRIVE-THRU / WALK-UP WINDOW ASSEMBLY - VERIFY REQUIREMENTS AND THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />SELECTION W/ OWNER/TENANT - COORDINATE INSTALLATION WITH ALL RELATED INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />TRADE - SILL HEIGHT TO BE 34" MAX. A.F.F. AT INTERIOR - SEE DETAILS 2 & 3/AD5 <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />9. STEEL DOOR AND FRAME - FACTORY PRIMED AND FIELD PAINTED - SEE EXTERIOR "api' AND IS NOT TO BE USED, IN WHOLE OR IN <br />ELEVATIONS AND DOOR SCHEDULE PART, FOR ANY OTHER PROJECT WITHOUT <br />10, PROVIDE A MINIMUM OF 12" CLEAR AT INTERIOR AT STRIKE SIDE OF OUTSWINGING WRITTEN AUTHORIZATION. <br />EXTERIOR DOORS -TYPICAL <br />11. PROVIDE A MINIMUM OF 24" CLEAR AT EXTERIOR STRIKE SIDE OF EXTERIOR DOORS - <br />TYPICAL <br />12, PRAON IDE MIN. 60" x 60" CLEAR AND LEVEL LANDING AT EXTERIOR DOORS - SEE 517E PLANNING ®® <br />13. INDICATES SAFETY TEMPERED GLAZING - TYPICAL - SEE SCHEDULES SHEET A7.1 ARCHITECTURE 0 5 <br />14. LINE OF CANOPY ABOVE - SEE EXTERIOR ELEVATIONS & CANOPY ROOF PLAN <br />15. DASHED LINE INDICATES EXHAUST HOOD ABOVE -SEE MECHANICAL DRAWINGS <br />16. LOCATION OF TELEPHONE BACKBOARD ABOVE CEILING - SEE ELECTRICAL <br />DRAWINGS <br />17. LOCATION OF ELECTRICAL MAIN METER PANEL - INSTALL PERMANENT ALL WEATHER <br />SIGNAGE STATING "MAIN ELECTRICAL DISCONNECT' IN MIN. &' HIGH LETTERS AND IN <br />CONTRASTING WHITE/RED BACKGROUND/LETTERS -SEE ELECTRICAL DRAWINGS a F) <br />18, LOCATION OF ELECTRICAL SUB PANEL - SEE ELECTRICAL DRAWINGS <br />19. INDICATES LOCATION OF GAS METER - PROVIDE RISERS THROUGH WALL TO TRUSS <br />SPACE - INSTALL PERMANENT ALL WEATHER SIGNAGE STATING "MAIN GAS SHUTOFF" <br />IN MIN. 3" HIGH LETTERS AND IN CONTRASTING WHITE/RED BACKGROUND/LETTERS - <br />i* SEE PLUMBING PLANS <br />6- 20. ACCESSIBLE SINGLE -ACCOMMODATION RESTROOM - SEE ENLARGED RESTROOM ARCHITECTURE PLUS INC, <br />PLAN 2/A2 AND DETAILS 10 THROUGH 12/AD1 4335-B NORTH STAR WAY <br />21, FIRE EXTINGUISHER AND CABINET -TYPICAL -VERIFY LOCATIONS WITH FIRE MARSHAL MODESTO, CA 95356 <br />PROVIDE (1) 2A:103C FIRE EXTINGUISHER EVERY 75WALKING DISTANCE THAT IS NOT <br />MORE THAN 4' FROM THE FLOOR - FIRE EXTINGUISHER TO BE LOCATED NEXT TO MAN <br />DOOR - DISPLAY A CURRENT STATE FIRE MARSHAL SERVICE LABEL PER CFC 1002 ph. 209.577.4661 <br />22. PROVIDE A TYPE K FIRE EXTINGUISHER WITHIN 30 FEET OF THE HOOD PER 904.11.2 CFC fx. 209.577.0213 <br />23. ROOF ACCESS LADDER - SEE DETAILS 4/A5,4 <br />24. INDICATES INTERNATIONAL SYMBOL OF ACCESSIBILITY - TYPICAL - MOUNT ADJACENT <br />TO THE LATCH, OUTSIDE OF THE DOOR, OR ON THE NEAREST ADJACENT WALL OR www.apiarc.com <br />GLAZING - MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE <br />CENTERLINE OF SIGN - PER CBC 11 B-216.6 <br />25. TACTILE EXIT / EXIT ROUTE SIGN - SEE DETAIL 7/ADI <br />26. INDICATES RAIN WATER LEADER IN WALL -SEE ROOF PLAN, PLUMBING AND CIVIL <br />DRAWINGS FOR ADDITIONAL INFORMATION <br />27. INDICATES RAIN WATER LEADER - SEE ROOF PLAN, PLUMBING AND CIVIL DRAWINGS FRANK C. BOOTS <br />FOR ADDITIONAL INFORMATION <br />JOSEPH L. SMITH <br />28. INDICATES LOCATION OF RECESSED HOSE BIB - PAINT TO MATCH - RECESS IN WALL - RODNEY C. ALONZO <br />PROVIDE BACKFLOW PREVENTION DEVICE PER CITY OF TURLOCK STANDARDS - SEE <br />PLUMBING PLANS ARCHITECTS <br />29. PROVIDE 5/8" TYPE 'X' GYPSUM BOARD BEHIND STAINLESS STEEL AND BEHIND ALL <br />COOKING EQUIPMENT - SEE FINISH PLAN / SCHEDULE Q <br />30. PROVIDE 5/8" TYPE'X' GYPSUM BOARD BEHIND FRP PANELS - TYPICAL IN KITCHEN U <br />AND RESTROOM - SEE INTERIOR ELEVATIONS AND FINISH PLAN / SCHEDULE <br />31. SEE SHEET K1.1 FOR EQUIPMENT LAYOUT <br />32. 24" SQ, MOUNTED MOP SINK - SEE PLUMBING DRAWINGS <br />33. AIR CURTAIN ABOVE - SEE ELECTRICAL DRAWINGS <br />34. FLOOR SINK - SEE PLUMBING DRAWINGS AND DETAIL 9/AD6 W <br />NOTES <br />• DIMENSIONS ARE TO FACE <br />OF STUD U.N.O. <br />• FACE OF SHEATHING TO <br />ALIGN WITH FACE OF CURB <br />• SEE STRUCTURAL DRAWINGS <br />FOR CURB DIMENSIONS <br />MINIMUM INSULATION <br />O <br />REQUIREMENTS <br />m <br />ER WALLS - R-19 BATT <br />ROOF <br />INTERIOR ELEVATION SYMBOL - SEE INTERIOR ELEVATIONS SHEET <br />* VERI <br />oz <br />WALL LEG <br />END <br />45. HIGH TABLETOP - SEE DETAILS 13 & 14/AD2 <br />STUD WALL <br />2X:6 <br />2 X 6 INTERIOR STUD WALL <br />38. <br />METAL STUD, WALL <br />47. 18" HIGH CONCRETE CURB - SEE DETAIL 12/AD2 <br />COOLERWALL- BYOTHERS <br />39. <br />PROVIDE SIGN ABOVE DOOR TO READ "THIS DOOR TO REMAIN UNLOCKED WHEN <br />b <br />"i <br />N OTE: <br />THIS SPACE IS OCCUPIED" PER CBC 1010,1.9.3 <br />cv <br />1. PROVIDE 2A14 -BC WITHIN 75' OF EXITS AND 3,000 S.F. IN GENERAL USE AREAS. FIRE <br />40. <br />WALL TO HAVE FULL HEIGHT STAINLESS STEEL AT AREA OF HOOD AND FULL HEIGHT <br />. <br />vq <br />) <br />a <br />i+7 <br />im <br />b" <br />CENTERLINE OF <br />COLUMN <br />14 6_ <br />------ ------- t:! <br />I <br />I 45 <br />I <br />25-3 7/8" 1 6'-2 1/4" <br />CENTERLINE OF <br />COLUMN <br />1 <br />13'-1" <br />4'-4., <br />V-6`` <br />CENTERLINE OF <br />I COLUMN <br />44'-7" <br />16-0" <br />2'-2" 6'-Z" <br />{ 38 <br />4 1 r- 717 10 1I I tv <br />A5.4 A5.1 I / I I RR I 6 I <br />6 <br />0 I 3 <br />0 I ?�.I r� _` i I <br />1 RESTROOM ...�. <br />SCALE: 3/9'= V-0' (TYPICAL) <br />ARESTROOM <br />4-41/2" 6'-1 1 1/2" <br />51-8" 11'4' 1. 27-7 <br />2'-6" 44'-7" <br />I <br />47--l" <br />FLOOR PLAN <br />SCALE: 1/4"= 1'-0" <br />ENLARGED RESTROOM PLAN <br />SCALE: 1/2"= V-9' <br />NORTH <br />15-6" <br />1 <br />ASA <br />tl.�o <br />23'-9" <br />FLOOR AREAS: 788 S.F. <br />mil *iii <br />FLOOR PLAN KEYNOTES: REVISIONS <br />1. DIMENSIONS ARE TO FACE OF STUDS -TYPICAL U.N.O. -SEE STRUCTURAL DRAWINGS <br />FOR FOUNDATION DIMENSIONS <br />2. 2 X 6 STUDS AT 16" OC EXTERIOR WALLS WITH BATT INSULATION ON 6" HIGH CURB - <br />FACE OF PLYWOOD SHEATHING TO ALIGN WITH FACE OF CURB - SEE DETAILS 1 <br />THROUGH 4/AD3 AND STRUCTURAL DRAWINGS FOR CURB/FOUNDATION DIMENSIONS <br />- PROVIDE 2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND <br />PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND <br />AT 10 FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 718.2.1 - <br />SEE STRUCTURAL DRAWINGS <br />3. 2 X 6 OR 2 X 4 STUDS (SEE LEGEND BELOW AT 16" O.C. AT INTERIOR WALLS - PROVIDE <br />2 X FIRE BLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, <br />INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS AND AT 10 FOOT <br />INTERVALS BOTH VERTICAL AND HORIZONTAL PER CBC SECTION 708.2.1 <br />4. 5 1/2" X 20 GA METAL STUDS AT 16" O.C. AT INDICATED EXTERIOR WALL <br />5. 3 5/8" X 25 GA METAL STUD 7'-0" HIGH WALL - SEE BUILDING SECTIONS SHEET ASA <br />6. STEEL COLUMN -SEE STRUCTURAL DRAWINGS <br />7. ALUMINUM STOREFRONT ASSEMBLY - TYPICAL - INSTALL PER MANUFACTURER'S <br />SPECIFICATIONS - SEE DOOR SCHEDULE AND WINDOW SCHEDULES <br />8. OPERABLE DRIVE-THRU / WALK-UP WINDOW ASSEMBLY - VERIFY REQUIREMENTS AND THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />SELECTION W/ OWNER/TENANT - COORDINATE INSTALLATION WITH ALL RELATED INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />TRADE - SILL HEIGHT TO BE 34" MAX. A.F.F. AT INTERIOR - SEE DETAILS 2 & 3/AD5 <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />9. STEEL DOOR AND FRAME - FACTORY PRIMED AND FIELD PAINTED - SEE EXTERIOR "api' AND IS NOT TO BE USED, IN WHOLE OR IN <br />ELEVATIONS AND DOOR SCHEDULE PART, FOR ANY OTHER PROJECT WITHOUT <br />10, PROVIDE A MINIMUM OF 12" CLEAR AT INTERIOR AT STRIKE SIDE OF OUTSWINGING WRITTEN AUTHORIZATION. <br />EXTERIOR DOORS -TYPICAL <br />11. PROVIDE A MINIMUM OF 24" CLEAR AT EXTERIOR STRIKE SIDE OF EXTERIOR DOORS - <br />TYPICAL <br />12, PRAON IDE MIN. 60" x 60" CLEAR AND LEVEL LANDING AT EXTERIOR DOORS - SEE 517E PLANNING ®® <br />13. INDICATES SAFETY TEMPERED GLAZING - TYPICAL - SEE SCHEDULES SHEET A7.1 ARCHITECTURE 0 5 <br />14. LINE OF CANOPY ABOVE - SEE EXTERIOR ELEVATIONS & CANOPY ROOF PLAN <br />15. DASHED LINE INDICATES EXHAUST HOOD ABOVE -SEE MECHANICAL DRAWINGS <br />16. LOCATION OF TELEPHONE BACKBOARD ABOVE CEILING - SEE ELECTRICAL <br />DRAWINGS <br />17. LOCATION OF ELECTRICAL MAIN METER PANEL - INSTALL PERMANENT ALL WEATHER <br />SIGNAGE STATING "MAIN ELECTRICAL DISCONNECT' IN MIN. &' HIGH LETTERS AND IN <br />CONTRASTING WHITE/RED BACKGROUND/LETTERS -SEE ELECTRICAL DRAWINGS a F) <br />18, LOCATION OF ELECTRICAL SUB PANEL - SEE ELECTRICAL DRAWINGS <br />19. INDICATES LOCATION OF GAS METER - PROVIDE RISERS THROUGH WALL TO TRUSS <br />SPACE - INSTALL PERMANENT ALL WEATHER SIGNAGE STATING "MAIN GAS SHUTOFF" <br />IN MIN. 3" HIGH LETTERS AND IN CONTRASTING WHITE/RED BACKGROUND/LETTERS - <br />i* SEE PLUMBING PLANS <br />6- 20. ACCESSIBLE SINGLE -ACCOMMODATION RESTROOM - SEE ENLARGED RESTROOM ARCHITECTURE PLUS INC, <br />PLAN 2/A2 AND DETAILS 10 THROUGH 12/AD1 4335-B NORTH STAR WAY <br />21, FIRE EXTINGUISHER AND CABINET -TYPICAL -VERIFY LOCATIONS WITH FIRE MARSHAL MODESTO, CA 95356 <br />PROVIDE (1) 2A:103C FIRE EXTINGUISHER EVERY 75WALKING DISTANCE THAT IS NOT <br />MORE THAN 4' FROM THE FLOOR - FIRE EXTINGUISHER TO BE LOCATED NEXT TO MAN <br />DOOR - DISPLAY A CURRENT STATE FIRE MARSHAL SERVICE LABEL PER CFC 1002 ph. 209.577.4661 <br />22. PROVIDE A TYPE K FIRE EXTINGUISHER WITHIN 30 FEET OF THE HOOD PER 904.11.2 CFC fx. 209.577.0213 <br />23. ROOF ACCESS LADDER - SEE DETAILS 4/A5,4 <br />24. INDICATES INTERNATIONAL SYMBOL OF ACCESSIBILITY - TYPICAL - MOUNT ADJACENT <br />TO THE LATCH, OUTSIDE OF THE DOOR, OR ON THE NEAREST ADJACENT WALL OR www.apiarc.com <br />GLAZING - MOUNTING HEIGHT SHALL BE 60 INCHES ABOVE THE FINISH FLOOR TO THE <br />CENTERLINE OF SIGN - PER CBC 11 B-216.6 <br />25. TACTILE EXIT / EXIT ROUTE SIGN - SEE DETAIL 7/ADI <br />26. INDICATES RAIN WATER LEADER IN WALL -SEE ROOF PLAN, PLUMBING AND CIVIL <br />DRAWINGS FOR ADDITIONAL INFORMATION <br />27. INDICATES RAIN WATER LEADER - SEE ROOF PLAN, PLUMBING AND CIVIL DRAWINGS FRANK C. BOOTS <br />FOR ADDITIONAL INFORMATION <br />JOSEPH L. SMITH <br />28. INDICATES LOCATION OF RECESSED HOSE BIB - PAINT TO MATCH - RECESS IN WALL - RODNEY C. ALONZO <br />PROVIDE BACKFLOW PREVENTION DEVICE PER CITY OF TURLOCK STANDARDS - SEE <br />PLUMBING PLANS ARCHITECTS <br />29. PROVIDE 5/8" TYPE 'X' GYPSUM BOARD BEHIND STAINLESS STEEL AND BEHIND ALL <br />COOKING EQUIPMENT - SEE FINISH PLAN / SCHEDULE Q <br />30. PROVIDE 5/8" TYPE'X' GYPSUM BOARD BEHIND FRP PANELS - TYPICAL IN KITCHEN U <br />AND RESTROOM - SEE INTERIOR ELEVATIONS AND FINISH PLAN / SCHEDULE <br />31. SEE SHEET K1.1 FOR EQUIPMENT LAYOUT <br />32. 24" SQ, MOUNTED MOP SINK - SEE PLUMBING DRAWINGS <br />33. AIR CURTAIN ABOVE - SEE ELECTRICAL DRAWINGS <br />34. FLOOR SINK - SEE PLUMBING DRAWINGS AND DETAIL 9/AD6 W <br />NOTES <br />• DIMENSIONS ARE TO FACE <br />OF STUD U.N.O. <br />• FACE OF SHEATHING TO <br />ALIGN WITH FACE OF CURB <br />• SEE STRUCTURAL DRAWINGS <br />FOR CURB DIMENSIONS <br />SYMBOL <br />MINIMUM INSULATION <br />O <br />REQUIREMENTS <br />PERIM <br />ER WALLS - R-19 BATT <br />ROOF <br />INTERIOR ELEVATION SYMBOL - SEE INTERIOR ELEVATIONS SHEET <br />* VERI <br />REQUIREMENTS WITH ENERGY CALCULATIONS <br />SYMBOL <br />�EGEND <br />O <br />DOOR SYMBOL - SEE DOOR SCHEDULE SHEET A7 <br />OAWINDOW <br />SYMBOLS - SEE WINDOW SCHEDULE SHEET A7 <br />22 <br />INTERIOR ELEVATION SYMBOL - SEE INTERIOR ELEVATIONS SHEET <br />37. <br />FINISH SYMBOL -'.SEE FINISH SCHEDULE SHEET A7 <br />WALL LEG <br />END <br />45. HIGH TABLETOP - SEE DETAILS 13 & 14/AD2 <br />STUD WALL <br />2X:6 <br />2 X 6 INTERIOR STUD WALL <br />38. <br />METAL STUD, WALL <br />47. 18" HIGH CONCRETE CURB - SEE DETAIL 12/AD2 <br />COOLERWALL- BYOTHERS <br />35, <br />FLOOR DRAIN - SEE PLUMBING DRAWINGS <br />N <br />42. DRIVE-THRU CONDUITS - SEE ELECTRICAL DRAWINGS <br />36. <br />MANAGER'S DESK WITH SHELF ABOVE - PROVIDED BY OWNER - SEE DETAIL 4/AD7 <br />43. SODA CHASE IN WALL - SEE PLUMBING DRAWINGS <br />37. <br />S/S CORNER GUARDS ON ALL OUTSIDE CORNERS - TYP. AT KITCHEN - SEE INTERIOR <br />■ <br />45. HIGH TABLETOP - SEE DETAILS 13 & 14/AD2 <br />ELEVATIONS AND DETAIL 3/AD7 <br />Z <br />38. <br />CO2 FILL <br />47. 18" HIGH CONCRETE CURB - SEE DETAIL 12/AD2 <br />39. <br />PROVIDE SIGN ABOVE DOOR TO READ "THIS DOOR TO REMAIN UNLOCKED WHEN <br />te- <br />N OTE: <br />THIS SPACE IS OCCUPIED" PER CBC 1010,1.9.3 <br />u <br />1. PROVIDE 2A14 -BC WITHIN 75' OF EXITS AND 3,000 S.F. IN GENERAL USE AREAS. FIRE <br />40. <br />WALL TO HAVE FULL HEIGHT STAINLESS STEEL AT AREA OF HOOD AND FULL HEIGHT <br />. <br />vq <br />) <br />a <br />FRP PANELS ON REMAINING AREAS - SEE DETAIL 5/AD7 AND FINISH SCHEDULE <br />im <br />41. BOLLARD - SEE SITE PLANui <br />W <br />42. DRIVE-THRU CONDUITS - SEE ELECTRICAL DRAWINGS <br />Z <br />43. SODA CHASE IN WALL - SEE PLUMBING DRAWINGS <br />ui <br />44. SOLID SURFACE COUNTER AT +34" MAX A.F.F. - BY GENERAL CONTRACTOR <br />■ <br />45. HIGH TABLETOP - SEE DETAILS 13 & 14/AD2 <br />46. FLAT FRAMED INTERIOR WALL -SEE DETAIL S/AD3 <br />Z <br />47. 18" HIGH CONCRETE CURB - SEE DETAIL 12/AD2 <br />Q <br />te- <br />N OTE: <br />u <br />1. PROVIDE 2A14 -BC WITHIN 75' OF EXITS AND 3,000 S.F. IN GENERAL USE AREAS. FIRE <br />0 <br />MARSHALL TO DETERMINE LOCATIONS WITH EACH TENANT IMPROVEMENT <br />ENLARGED PLAN / INTERIOR ELEVATION KEYNOTES: <br />1. ACCESSIBLE SINGLE ACCOMMODATION RESTROOM - SEE DETAIL 10/ADI <br />2. ACCESSIBLE WALL HUNG LAVATORY - SEE PLUMBING PLANS AND SEE DETAIL I I/ADI <br />3. ACCESSIBLE WATER CLOSET -SEE PLUMBING PLANS AND DETAIL 12/AD1 <br />4. GRAB BARS WITH EXPOSED MOUNTING - SEE DETAIL 13/ADI <br />5, TOILET TISSUE DISPENSER - SEE DETAIL 12/ADI <br />O <br />6. RECESSED PAPER TOWEL DISPENSER -SEE DETAIL 6/ADI <br />z <br />7. SOAP DISPENSER - SEE DETAIL 6/ADI <br />8. WALL MOUNTED MIRROR - PROVIDE BACKING AS NECESSARY <br />O Z <br />9. GYPSUM BOARD WALL FINISH - SEE FINISH SCHEDULE & NOTES <br />00 <br />10, PROVIDE ACCESSIBILITY SIGNAGE - SEE DETAIL S/ADI <br />w j <br />11. 30" x 48" CLEAR FLOOR AREA <br />z a� u- <br />Q�w <br />12, 60" DIAMETER TURNING SPACE <br />fl- UJ <br />o � <br />13. FLOOR DRAIN - CENTER IN RESTROOM - SEE PLUMBING DRAWINGS <br />0 Q af <br />14. DOOR AND FRAME - PROVIDE DOOR MOUNTED RESTROOM SIGNAGE - SEE DETAIL <br />w <br />O__j z Z <br />VADI <br />U- Lu - <br />NOTES: <br />1. PROVIDE BACKING AS REQUIRED FOR WALL MOUNTED FIXTURES AND ACCESSORIES <br />-SEE DETAIL 14/ADI <br />2, SEE ACCESSIBILITY DETAILS FOR ADDITIONAL INFORMATION AND DIMENSIONS <br />3. SEE FLOOR PLAN FOR COMPLETE WALL DIMENSIONS <br />EXITING: <br />AREA: 788 SQ_ FT. <br />OCCUPANCY GROUP: B <br />OCCUPANT LOAD: 5 -SEE PLAN FOR INDIVIDUAL AREAS/ROOMS <br />PER CBC TABLE 1006.3.2(2) 1 EXIT REQUIRED <br />EXITING: <br />K2 EXITS REQUIRED: 1 PER C.B.C. TABLE 1006.3.2(2) <br />EXITS PROVIDED: 1 <br />EXIT WIDTH CALCULATION: <br />OCCUPANT LOAD: 5 <br />DATE: <br />JANUARY 2018 <br />5 X 0.2 = 1" TOTAL MIN. <br />EXIT WIDTH PROVIDED: <br />JOB NO.: <br />18-004 <br />36" DOOR: 36" >I" THEREFORE OK <br />api CCPYRIGHT2017 <br />DRAWN . T. CORGIAT <br />CHECKED: F. BOOTS <br />SHEET: <br />m <br />