Laserfiche WebLink
' SOIL VAPOR EXTRACTION PILOT STUDY REPORT <br /> San Joaquin County <br /> Montgomery Ward Auto Service Center Public Health Services Department <br /> 5400 Pacific Avenue Stockton, CA Site Code 2163 <br />' 11.0 RECOMMENDATIONS <br />' Based on the conclusions, EAI recommends the following <br />' ■ VES be used to implement soil remediation at the site <br /> ■ The current configuration of wells and probes be used for VES <br />' ■ A thermal oxidizer VES unit with capacity of 200 to 300 scfm at 10 to 12 inches <br /> Mercury vacuum rating be utilized for the remediation <br />' 0 That the current VES wells on site be connected by piping (subsurface from the <br /> building to the well locations and aboveground at or above the building) to the VES <br /> unit <br />' EAI estimates that it will take approximately 12 to 18 months to complete the remediation <br /> using the above recommended system <br /> 12.0 LIMITATION <br /> Our professional services have been performed using that degree of care and skill ordinarily <br /> exercised, under similar circumstances, by reputable environmental consultants practicing in <br /> this or similar localities This report has been prepared for Montgomery Ward & Co , <br /> Incorporated The conclusions and recommendations included in this report are based on <br /> information contained or referenced herein, and our best judgment No other warranty, <br /> expressed or implied, is made as to the professional advice contained in this report <br /> IRespectfully submitted, <br /> ENVIRONMENTAL AUDIT, INC <br /> LI <br /> Walild M Kazi, cvr'� <br /> AiPhD , R Principal Geologista,7 �f <br /> I <br /> I <br /> IProject No 1232 - 18 - ENVIRONMENTAL AUDIT, INC <br />