Laserfiche WebLink
t}w <br /> MINIMUM VERIFICATION LABORATORY ANALYSIS <br /> OXYGENATES <br /> TANK TPH-G TPH-D BTX&E CL HC TOTAL MTBE (MTBE, METALS PCB <br /> CONTENTS 8015 8015 8020 8010 LEAD 8020 TBA,DIPE, ICRP/ 8270 <br /> 8260 8260 8260 8240 7420 8260 ESE' AES or <br /> TAME) AA 8080 <br /> 8260 7421 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR. X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTSX X <br /> WASTE\ <br /> USED OIL X X X X X X X <br /> All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW <br /> 846 are specifically noted below. Refer to the"SWRCB LUFT Field Manual",Appendix D(B),Table 3-5 on page A20 for <br /> minimum detection limits for motor vehicle fuel(gasoline and diesel). Refer to"Tri-Regional Board Staff Recommendations for <br /> Initial Evaluation and Investigation of UST's"for the waste and motor oil minimum detection limits. <br /> Detection Limits that remain below the MCL,STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline,GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,GC/FID(3550),8015 mod or GC/MS 8260 <br /> BTX&E Benzene,Toluene,Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GC/MS 8240 or 8260 <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICP-AES 6010 <br /> OXYGENATES MTBE,ETBE,TAME,DIPE,&TBA GC/MS 8260(For MTBE screen-only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. <br /> Metals:Cadmium,Chromium III and VI,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation . <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are preferred to packed <br /> columns;a packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have been characterized and proper QA/QC <br /> is followed. <br /> For drinking water sources,EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the <br /> detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis.EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 10/16/03) Page 8 <br />