My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COMMERCE
>
190
>
1600 - Food Program
>
PR0545130
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2022 1:22:52 PM
Creation date
4/3/2020 1:49:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545130
PE
1624
FACILITY_ID
FA0025671
FACILITY_NAME
ONO HAWAIIAN BBQ
STREET_NUMBER
190
STREET_NAME
COMMERCE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
190 COMMERCE AVE STE 104
P_LOCATION
04
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOOD SERVICE EQUIPMENT LIST - STANDARD STORE- AUGUST 2018 <br /> E <br /> ITEM BY QTY DESCRIPTION MFG/ MODEL ADD INFO m � o co Misc. HEALTH DEPARTMENT NOTES o Q 0 <br /> L <br /> � 1. ALL NEW EQUIPMENT SHALL MEET NSF STANDARDSu ,n a <br /> m CD L <br /> 1 0 LOT CHAIRS TABLES AND BENCH FOLLOW ONO HAWAIIAN MATERIAL (NATIONAL SANITATION FOUNDATION 36 'T 2 <br /> STANDARDS BY ONO PROJECT MANAGER BOTTLE COOLER BY COKE )• a. � � <br /> COORDINATE WE PM / COKE 2. WALLS AS INSTALLED BY GENERAL CONTRACTOR SHALL BE <br /> O KES 1 AIR CURTAIN MARS AIR SYSTEM MODEL N0. 36' THOS, UNHEATED 1/2HP MOTOR WITH ¢ � <br /> N236-1UA-TS 115V CONTROLLER AND DOOR UNIT NONABSORBENT EASILY WASHABLE SURFACE, LIGHT IN < Q v <br /> GC 1 SODA COUNTER PROVIDE STRUCTURAL SUPPORT <br /> SWTCH-TITANIUM SILVER COLOR WITH A 70% LIGHT REFLECTIVE VALUE. SEE ARCH, o = <br /> O MAX 34" AFF- FOLLOW PMS SODA DRAWINGS FOR FINISH AND SPECIFICATIONS. Lu LO Q <br /> CUSTOM MILLWORK W/ QUARTZ TOP COUNTER LAYOUT wElf <br /> OcCv <br /> 0 2 ICE TEA DISPENSER <br /> 3. CELILING AS INSTALLED BY GENERAL CONTRACTOR SHALL <br /> 4 FROM COCA-COLA - UL/ NSF 115V 1/2" F S TEA TOWER BY COKE GC TO COORDINATE BE NONABSORBENT EASILY WASHABLE SURFACE, LIGHT IN <br /> SERVER PRODUCTS NO. 83220 - <br /> FOLLOW Pus SODA COUNTER LAYOUT <br /> O 00 <br /> GC 2 S/S SAUCE PAN OR APPROVED ONO STANDARDS FOLLO COLOR WITH A 70% LIGHT REFLECTIVE REFLECTIVE VALUE. <br /> CP-8-1/2 CONDIMENT NON-PERFORATED VINYL ACOUSTICAL CEILNG TITLES WITH c0 <br /> PMS SODA COUNTER LAYOUT INTREGAL WHITE POWER COATED METAL CEILING GRID <br /> SODA DISPENSER WITH ICE MACHINE SODA DISPENSER: LANCER IBD 4500 SERIES B PROVIDE APPROVED WATER FILTER FOR SOD <br /> 6 0 1 COKE— ICE MAKER— SEE ITEM 44 SEE MFG MAAY BE USED AS APPROVED BY THE LOCAL <br /> LOCATED ABOVE-WATER FILTER WATER FILTER: ICOMATIC SPECS 1/2 F.S. AND ICE AND PROVIDE A BACKFLOW ENVIRIMENTAL HEALTH DEPARTMENT OR GOVERNING <br /> PREVENTER AGENCY. <br /> O GC 1 FRONT CASHIER COUNTER CUSTOM MILLWORK BY G.C. MAX 34" AFF- FOLLOW PMS COUNTER O�-- <br /> LAYOUT 4. FLOORS AS INSTALLED BY GENERAL CONTRACTOR SHALL 0 <br /> O$ 0 3 POS PROVIDE 3 1" CONDUITS, BE <br /> CONTACT CORPORATE 115V AND (2) QUAD RECEPTACLES ABELOW <br /> E RADIUS COVE BASE AT ITHE WFLOOR/WALL TJUNCTURE AND GC TO BACKING Y FOR PLYWOOD <br /> OGC 1 STAINLESS STEEL BACK COUNTER CUSTOM BUILT BY GC EXTEND 4" TO 6" UP WALL. FLOORS SHALL SLOPE TO A MOUNTED SHELVING- AT 4$c°�1$ 361x1$ 4$cm18 LL 1111 48�6}1 g (7 <br /> W/ 6" HIGH SS LEGS SEE DETAILS ON A6.0 WALL APPROX LENGTH Cn <br /> FLOOR DRAIN (1:50 MIN, SLOP) OR PER LOCAL 14 <br /> 18" WIDE STAINLESS SHELF GOVERMENT AGENCY HAVING JURISDICTION OVER PROJECT. 13'- (2) ROWS OF FREEZER W/ FLOOR AND w <br /> 10 <br /> cc 1 ENTIRE LENGTH OF PASS THRU PROVIDE 1.5" HOLE FOR POS COORDINATE SEE ARCH. DRAWII�FORFINISH AND SPECIFIC,4TlONS. SHELVING MOUNTED AT 66" � �-� 0 <br /> 50" AFF HIGH PASS THRU COUNTER CUSTOM BY GC NTH ONO PM FOR APPROVAL- SEE PLANFOR LENG -- � 43 q0 I 20 a° APPROVED RAMP BY MFG <br /> 11 KEC PLAN DRY STORAGE SHELVING METRO SHELF W/ 6" LEGS GREEN SHELVES BY ACTION SALES OR AND 84" AFF. NOTE: SELF CONTAINED <br /> 5 TIER 5. POT SINKS SHALL FABRICATED OF QUALITY GRADE 14 MODEL- NO FLOOR SINK <br /> BETTER- BOTT SHELVING TO BE 6" AFF - - -00 <br /> x_R <br /> MINIMUM 14 GAUGE 300 SERIES TYPE STAINLESS STEEL, REQUIRED THIS DRAWING IS AN INSTRUMENT OF <br /> 1 rj GC DROP-IN HAND SINK SERVICE AND AS SUCH SHALL REMAIN <br /> L 1 yy HHS15-KS / PROVIDE S.S. PAPER TOWEL AND WITH THREE COVE SINK BOWLS LARGE ENOUGH TO / ® 48(�1 8 36«1 8 48M 1 <br /> 8M1 8 4$(°}1$ rHE PROPERTY OF NEPTUNE DESIGN <br /> / LEVER TYPE FAUCET REQ'D 1/2" 1 2" GROUP LLE UNAUTHORIZED <br /> SOAP DISPENSER ACCOMODATE LARGEST KITCHEN UTENSIL, WITH DUAL �-� 11USEOF <br /> O KESHENG STAINLESS STEEL G _ REPRODUCTION WITHOUT PERMISSION <br /> 13 KE$ � WALL MOUNT HAND SINK/ W GUARD PROVIDE S.S. PAPER TOWEL AND SOAP DRAINBOARDS AS LARGE AS THE LARGEST SINK \S'�'�/ OF THE ARCHITECT ISPROHIBITTED. <br /> W/ LI=VER TYPE FAUCET REQ'D HHS15S-K5 1/2" 1/2" DISPENSER- EQUIPED W/ SPLASH COMPARTMENT. ti� I8 11 18 _ THIS DRAWING IS ONLY FOR USE IN <br /> J� GUARD BY GSW - 11 PROVIDE CHASE FOR CONNECTION WITH THIS PROJECT AND <br /> GC 3 S/S WORK TABLE GSW (SIM #41) WITH CUT BUTS 48 SHALL NOT BE USED FOR OTHER <br /> 14 OR CUSTOM W " #4 ) FOOD PREPARATION SINK ARE REQUIRED SEPARATE FROM �� 60 O SYRUP LINES FROM BAG IN LOCATIONS COPYRIGHT2017 <br /> SEE ONO CORP(SIZE SEE PLAN) / 5 BACK SPLASH (SEE 1 OR CUSTOM FABRICATION 11 37 55 - BOX-(3) 3" DIA PVC <br /> BY GC. GC TO FOLLOW PLAN POTWASHING AND HAND SINKS. FOOD PREPARATION SINK 19 <br /> ALTERNATE: CUSTOM BUILT PER MUST HAVE AND INDIRECT WASTE TO A FLOOR SINK. 50 <br /> 15 GC 1 3 COMPARTMENT SINK GSW-SH18243D 1/2" 1/2" SEE ONO STANDARDS- SEE PLUMBING -�-__�� - <br /> 18"X24" BIN W/ 18" DRAIN BOARDS PLUMB PLANS FOR CONNECTION TYPE 7. ALL ICE MACHINES SHALL BE LOCATED WITHIN THE 17 18 48 33 <br /> 16 GC 1 2 COMPARTMENT PREP SINK GSW SH18242D „ SEE ALTEA U L BUILDING IN AND EASILY CLEANABLE WELL VENTILATED 34 15 34 33 16 13 <br /> 18"X24 BIN W/ 18 DRAIN BOARDS 1/2" 1/2" PLUMB ONO STANDARDS- SEE PLUMBING AREA AND SHALL HAVE AND INDIRECT WASTE TO A FLOOR 0 <br /> PLANS FOR CONNECTION TYPE SINK. BY MEANS OF AND INDIRECT WASTE WITH LEGAL AIR #19 LOCATED MOUNTED ELEC _ _ <br /> 17 cc 1 WATER HEATER Lu <br /> SEE PLUMBING SHEETS SEE PLUMBING AND ARCH DETAILS GAP. BELOW WATER HEATER 7 -- CORDINATE SHELVING <br /> SHELF ON BACK WALL ELEC AND CABINETS WITH 0 CD <br /> 18 GC 1 MOP SINK GSW USA MODEL NO: SE2424FM MOPSINK 8. ALL FOOD RELATED EQUIOMENT - FOOD SINKS ICE CORPORATE to M <br /> INCLUDES PLASTIC BASKET STRAINER MACHINES, REFRIGERATED EQUIPMENT, STEAM EQUIPMENT, ----q 1.n <br /> FLOOR MOUNT 21"W, 21"L, 9"D BOWL 3/4" 3/4" 2" W � <br /> AND SS CONSTRUCTION COOKING EQUIPMENT, ECT. SHALL DRAIN TO A FLOOR ELEC 4s <br /> 19 GC i SHELF STAINLESS STEEL WALL SHELF PER SINK. I I Q <br /> PLANS I I n QI <br /> _ w U <br /> SEE SHEET A4.0 FOR U <br /> 20 KEC 1 DUNNAGE RACK- FREEZER DNRK - 1424 OR ONO APPROVED EQ LIGHTING SHALL�BE INSTALLED TO PROVIDE 50 FOOT 25 26 41 45 24 23 22 22 I RESTROOM FIXTURES DC U <br /> CNFLES AT ALL FOOD PREPARATION AND WAREWASHING LL.I W <br /> CAPTIVE AIRS OR APPROVED EQ. AREAS. 50 FOOR CANDLES OF LIGHT SHALL BE PROVIDED 21 70 _ _ _ I <br /> 21 GC 1 TYPE 1 EXHAUST HOOD W/ FAN SEE H SHEETS. � � � � p �- � s=� = - � Z <br /> (SEE PLAN FOR SIZE) SEE H SHEETS SEE H SHEETE. IN ALL WALK-IN REFRIGERATION UNITS DRY FOOD) F - <br /> f00� INTERLOCK WITH M.U.A. STORAGE AREAS. LAVATORY AND RESTROOMS. AND ALL I <br /> 22 KEC 2 GAS RICE COOKER RINNAI RER-55AS FOOD SALES AREAS ALL LIGHTING INSIDE EQUIPMENT STAINLESS STEEL 27 33 28 29 30 27 I I r — Q Q <br /> 35,000 1/2" QUICK DISCONNECT GAS LINES REQUIRED RECESSED WELL- I I - - U <br /> FLOOR CASTERS ARE REQUIRED SHALL BE OF SHATTERPROOF CONSTRUCTION OR S - — - r I� - - 47 <br /> PROTECTED WITH SHATTERPROOF SHIELDS A HALL PROVIDE DRAIN F_ - � -` � Ii 1 f �� I I � 0 <br /> 23 KEC 1 6-OPEN BURNER WOLF MODEL- C36S-6B 215,000 1-1/2 QUICK DISCONNECT GAS LINES REQUIRED BE TO FS BELOW. 1 �Ii )11 O) <br /> FLOOR CASTERS ARE REQUIRED ® <br /> PROVIDE CLIP TO JOIN FRYERS I � � I <br /> 24 KEC 2 DEEP FRYER FRYMASTER GF14 100,000 3/4" QUICK DISCONNECT GAS LINES REQUIRED 10. PLUMBING CONTACTOR SHALL SUPPLY AND INSTALL MIXING 1 <br /> GRIDDLE KEATING 72X36FT-G EH I <br /> FLOOR CASTERS ARE REQUIRED VALVES ON ALL KITCKEN BARSINKS, HAND AND ALL <br /> o <br /> 25 KEC 1 <br /> 219,000 3 4" QUICK DISCONNECT GAS LINES REQUIRED LAVATORIES FOR 110 DEGREE MAX, HOT WATER SUPPLY. I � �1_ <br /> SIZE: 72" X 36" / PROVIDE CHICKEN PRESSER SEE ARCH. AND PLUMING DRAWINGS. - <br /> SIM #22 24" HIGH-GSW (E5-S3072) 1 12 9 10 9 9 51 <br /> 26 GC 1 GRIDDLE STAND <br /> OR CUSTOM BUILT SIZE: 72" X 30" 11. APPROVED VENTILATION THROUGHOUT ALL KITCHEN, 1 Q�® / \ <br /> 27 KEC 1 BEVERAGE AIR 5PE60HC-24M DISHWASHING, FOOD STOREAGE ROOMS, RESTRROMS, AND I 54 / 1 <br /> CHANGING ROOMS SHALL BE PROVIDE REASONBLY FREE I 33 4 <br /> OLD TABLE 115V S.C. PER NSF STANDARD - 7 <br /> FROM EXCESSIVE HEAT, STEAM, CONDENSATION, SMOKE, I _______________ <br /> 28 GC 1 3-WELL WARMER WELLS DROP-IN MODEL: TO BE INSTALLED ON STEAM TABLE VAPERS, ECT. AND REASONABLE CONDITION OF COMFORT ------ - <br /> SEE <br /> MOD-300TDM—AF 208V 1/2" F.S. FOR ALL EMPLOYEES WORKING WITHIN THE FACILITY. L <br /> STEAM TABLE CUT SHEET FROM ONO PAI <br /> 29 BACK COUNTER AND <br /> KEC 2 DIPPER WELLS GSW MODEL H5-DSROG <br /> 1/2„ F.S. GC TO COORDINATE DROP--IN MANAGERS STATION — - --�� ------ -_ —WITH STEAM TABLE <br /> KEC 2 MILLWORK BY GC 31 $ \ 8 7 42 <br /> RICE WARMER THUNDER GROUP SEJ22000 120V PROVIDE 2ND RICE COOKER BELOW ON CART <br /> 30 (PROVIDE REAR W/ 4" CASTERS) -6" AFF ON CASTERS PROVIDE SHOP / 1 <br /> ; 1 <br /> 31 KEC 1 BOTTLE COOLER TRUE GDM-4ICPT-48LD DRAWINGS <br /> S.C. <br /> GC TO CONFIRM MFG SPECS 115V CROUGH OPENING 49" WIDE X 54" HIGH WITH EQUIPMENT KEY #48: G.C. TO PROVIDE (3) 1" CONDUITS FROM L o — _ / I 47 <br /> WALL MOUNTED METAL CABINETGSW USA MODEL NO A" CASIERS CEILING TO INSIDE CABINETS & TO SERVICE COUNTER AS NEEDED. _ <br /> 32 KEC 1 LOCKER, 6 ITER 12"x20"D X 77" H W 6" MOUNTED ON WALL 6" AFF PER HEALTH G.C. TO PROVIDE WALL JACKS FOR ALL UTILITY LINES INCLUDING <br /> EMPLOYEE LOCKERS LEGS. VENTED WITH BEIGE � I — <br /> POS. CLEANLY CONNECTED TO THE WALL. G.C. TO PROVIDE POWER a CASTERS REQUIRED <br /> 33 cc SEE FLOOR SINK TO (2) DUAL GANG BOX / RECEPTACLES INSIDE THE CABINET. GC TO CONSULT I _ _L_ FOR MERCHANDISE <br /> PLAN SEE PLUMBING PLANS 2" PER DETAIL 1/A6.0 TENANT FOR _ <br /> POWER FAN AS REQ. r -` — ° — DISPLAY <br /> 34 GC SEE WALL MOUNTED WALL SHELF Metro Erecta 12WS52C 16" & 18" DEEP — — <br /> PLAN (STACKED) 2 TIER Chrome Shelf Wall G.C. TO PROVIDE CABINET LOCKS, HINGES, BOOTH/ BENCH <br /> i 1 <br /> PROVIDE PLYWOOD BACKING STOPPERS AND SPECS SUPPLY 1 <br /> GUARDS. CABINET DOORS SHOULD BE TIGHTLY IN PLACE. 1 I d <br /> SHOP DRAWINGS I I <br /> 35 KEC 1 4' COLD TABLE BEVERAGE AIR- SPE48HC-18M 115VS.0FOR REVIEW AND. PER NSF STANDARD - 7 I o O I <br /> I I <br /> 37 0 LOT BAG IN BOX OR E _p AL BY SODA'VENDOR APPROVAL 19.75 D BY COKE- GC TO COORDINATE DELIVER <br /> I o <br /> 38 GC 2 TRASH BIN WASTE ENCLOSURE - CUSTOM o <br /> PROVIDE WASTE AND RECYCLE OPENINGS PROVIDED BY GC 1ICE MACHINE ABOVE <br /> 1 1 6 WATER FILTER UNDER <br /> 39 0 3 WASTE CONTAINER PROVIDE CONTAINER FROM ACTION GC TO SUPPLY SHOP i I I � 2 0 � I <br /> SALES PROVIDED BY GC CABINET <br /> DRAWINGS FOR I a �� , I <br /> 40 GC 1 WALK-IN COMBO RUSSEL OR APPROVED EQUAL SEE MFG SPECS SEE SELF CONTAINED- FREEZER EQUIPED COMMUNAL TABLES 1 I I 33 4 -�� iso <br /> MFG W/ FLOOR- NO FLOOR SINK REQUIRED 1 I I / 44 5 \ <br /> 41 GC 1 KEATING GRIDDLE STAND SEE ITEM 45- TO MATCH W/CASTERS L <br /> 1 ' 1 �� ' DATE: 10.17,2018 <br /> i I I <br /> 42 GC 2 SAFE CSS— CS2820 DROP SAFE OR PROIADE CLEARANCE FOR 2 SAFE 32" MIN sELO REVISION <br /> APPROVED EQUAL BY PM SERVICE COUNTER PROVIDE CONDUIT AND WALL L_ - _ i i \ / <br /> WALK—IN COOLER METAL THUNDER GROUP NSF GREEN EPDXY WIRE JACK FOR CONNECTIONS I I \ / <br /> 43 GC 1 SHELVING SHELVING AND POSTS FOR WALKIN SHELVING COORDINATE FROM ACTION SALES -GC MUST <br /> OR APPROVED ONO STANDARD SUPPLY SHELVING TO MEET DIMENSION OF WALLS --�-- 38 Q <br /> 44 GC 1 ICE MAKER (ABOVE SODA) HOSHIZAKI— KMD-860MAJ— SEE #6 PROVIDE APPROVED WATER FILTER FOR SOD <br /> 115V F.S. AND ICE AND PROVIDE A BACKFLOW <br /> PREVENTER II Q <br /> 45 GC 1 36" GRIDDLE KEATING MIRACLEAN 36X36FT 109,500 3/4" QUICK DISCONNECT GAS LINES REQUIRED <br /> I4 <br /> FLOOR CASTERS ARE REQUIRED <br /> 48 GC 2 STAINLESS STEEL PARTITION GSW MODEL SP-2018 �3 <br /> FROM TOP OF FRYER-20.5" LENGTH <br /> 11A f? <br /> 47 GC <br /> 2 ELECTRIC HAND BLOWER EXERATOR:XL-SB-ECO ADAPTOR NEEDEE FOR w/ SOUND & SPEED CONTROL ANTI q 01 <br /> (RESTROOM) RECESS {CONFIRM IF RECESSED IN WALL ) SEE MFG SPECS MICROBIAL WALL GUARDS XCHANGE PAPER I /� <br /> TOWEL DISPENSER RECESSED IN WALL v � <br /> 4$ GC 1 OFFICE CABINET BELOW WITH CONFIRM INSTALLATION WITH <br /> PERFERATED DOORS AND FAN CORPORATE 115V SEE NOTE ON A5.0 DAVID At1DKOW -A <br /> 49 GC G8912 <br /> 4 DECORATIVE WALL DESIGN BY ONO PROJECT MANAGER PROVIDED BY GC \`, E Q U�P M E N T FLOUR PLAN <br /> / �- <br /> HOSHIZAKI- KM-650MAJ w 07/3112019 <br /> 50 GC 1 ICE MACHINE W/ BIN BIN _ B_SOOSF 115V PROVIDE APPROVED WATER FILTER FOR 500 I SCALA: 114"= 1'-0" >, = i-- - ��- <br /> F.S. AND ICE AND PROVIDE A BACKFLOW N,_i <br /> 4T art�ATP � <br /> 51 GC 4 DIGITAL MENU BOARD CONFIRM INSTALLATION WITH PROVIDE ELECTRICAL DIRECTLY �OP At 0 <br /> CORPORATE- 48-DIAL 42"X24" 115V BEHIND MENU BOARD <br /> 52 GC 1 DRIVE THRU SODA DISPENSER LANCER-CONFIRM MODEL AND SIZE PROVIDE APPROVED WATER FILTER FOR SOD <br /> W/ BUILT IN ICE BIN 115V F,S, AND ICE AND PROVIDE A BACKFLOW EQUIPMENT PLAN <br /> 53 GC 0 BEVERAGE REFRIGERATOR W/ BEVERAGE -AIR OR EQUAL- MAX DEPTH PWWNTFR <br /> SLIDING GLASS DOOR ALLOWED-24" - MAX WIDTH 27" 115V <br /> 54 GC 1 DRIVE THRU AIR CURTAIN QUIK SERV CF-25 <br /> 115V <br /> A5 . 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.