My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5756
>
2900 - Site Mitigation Program
>
PR0527591
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2020 2:11:39 PM
Creation date
4/3/2020 2:05:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0527591
PE
2960
FACILITY_ID
FA0018695
FACILITY_NAME
ROBINHOOD PLAZA/C & S CLEANERS
STREET_NUMBER
5756
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
10227010
CURRENT_STATUS
01
SITE_LOCATION
5756 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mike Infurna [EH] <br /> From: Roberto Cervantes [RCervantes@waterboards.ca.gov] <br /> Sent: Friday, June 05, 2009 4:59 PM <br /> To: Scott.Seyfried@Ifr.com <br /> Cc: Duncan Austin <br /> Subject: Robinhood Shopping Center <br /> Scott, <br /> Regional Water Board staff has reviewed the submittal entitled "Work Plan to Conduct <br /> a Soil Vapor Extraction Pilot Test' submitted by LFR on behalf of Robinhood Shopping <br /> Center dated 15 May 2009. The report summarized previous sampling results and <br /> proposed an SVE pilot test. <br /> The highest concentrations of PCE in soil gas occur inside the dry cleaning facility <br /> near the dry cleaning machine. The highest soil gas concentration was reported as <br /> 8,700 ug/m3 and was located immediately adjacent to the dry cleaning machine. LFR <br /> proposes to test one location for vapor flow. If adequate flow is unable to be induced <br /> at that location, than another location near the dry cleaning machine will be flow <br /> tested. The flow test consist of a "stepped rate" test and a "constant rate" test. If <br /> adequate flow is induced in a test location, a full scale SVE system will be designed <br /> based on the data collected from the tests. LFR will submit the results of the pilot test <br /> and design parameters of the SVE system for Regional Board review and <br /> concurrence. <br /> Please contact me with all questions and concerns at 916 284 5449 or via <br /> email...thanks <br /> Roberto Cervantes <br /> Site Cleanup Program <br /> Central Valley Regional Water Quality Control Board 11020 Sun Center Drive, #200 <br /> Rancho Cordova, CA 95670 <br /> 916.464.4682 direct <br /> t <br />
The URL can be used to link to this page
Your browser does not support the video tag.