My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_TEMPORARY SOIL GAS PROBE PERMIT APPLICATION PACKAGE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
2711
>
2900 - Site Mitigation Program
>
PR0527620
>
ARCHIVED REPORTS_TEMPORARY SOIL GAS PROBE PERMIT APPLICATION PACKAGE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2020 2:12:48 PM
Creation date
4/3/2020 2:10:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
TEMPORARY SOIL GAS PROBE PERMIT APPLICATION PACKAGE
RECORD_ID
PR0527620
PE
2959
FACILITY_ID
FA0018715
FACILITY_NAME
LEARNER COMPANY, THE
STREET_NUMBER
2711
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2711 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' SOP TO-14A/15 <br /> Rev 4 <br /> December 2007 <br /> ' 16.1 Initial Calibration (ICAL) <br /> ' Prior to performing sample analysis,the GC must be initially calibrated. Following a clean blank analysis, at <br /> least five levels (only three are required for some regulatory areas)of target compounds along with <br /> surrogates and internal standards are introduced into the GUMS system and the total area under each peak <br /> ' determined. These values are entered into the software. The computer will construct the calibration curve <br /> according to one of several methods. Hardcopy output of the chromatograms should be saved and kept with <br /> the instrument throughout the lifetime of the ICAL. The hardcopy output should list the method used to <br /> ' generate the ICAL curve. The ICAL is considered valid until the continuing calibration fails or a major <br /> change in the instrument operating condition occurs. <br /> ' 16.2 Tune/Continuine Calibration (CCAL) <br /> The BFB tune as outlined in section 8.2 must be performed prior to analysis of any standards and repeated <br /> ' every 24 hours if samples or standards are to be analyzed. The calibration of the instrument is checked prior <br /> to analyzing samples and repeated every 24 hours if samples or standards are to be analyzed. The continuing <br /> calibration (CCAL)or continuing calibration verification (CCV)is analyzed to check the validity of the <br /> ' ICAL. Normally a standard corresponding to the midpoint of the curve is chosen. Response of the <br /> compounds of interest must be within that specified by the method (<30%RPD Aith a m axifflufn a f2 401.) <br /> for the continuing calibration check compounds (CCCs) for the curve to be valid. If not all compounds are <br /> ' of interest only those being analyzed need to be checked. The analyst may repeat a CCV if the CCV does <br /> not pass. <br /> ' 16.2.1 For work performed under the National Environmental Laboratory Accreditation Program (NELAP) <br /> 16.2.1.1 If the second CCV does not pass, it will require two consecutive CCV analyses in order to <br /> pass the criteria or a new valid initial calibration. <br /> 16.3 Detection Limits <br /> 16.3.1 Minimum Detection Limit <br /> The method detection limit(MDL) is the minimum concentration of a substance that <br /> ' can be measured and reported with 99 percent confidence that the analyte <br /> concentration is greater than zero. The laboratory shall establish MDLs for each <br /> method, matrix, and analyte for each instrument the laboratory plans to use for the <br /> ' project. The laboratory shall revalidate these MDLs at least once per twelve-month <br /> period. The laboratory shall maintain proof of the MDL demonstrations (i.e., before <br /> project samples are analyzed) and upon request in the format specified in Section 8. <br /> Results less than or equal to the MDL shall be reported as the MDL value and/or <br /> ' reported as non-detect("nd")with the reporting limit value clearly shown. <br /> Laboratories participating in the work effort shall demonstrate the MDLs for each <br /> instrument, including confirmatory columns, method of analysis, analyte, and matrix <br /> (i.e., water and soil) using the following instructions: <br /> Page 20 of 24 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.