Mike Infurna [EH] <br /> From: Mike Infurna [EH] <br /> Sent: Tuesday, August 18, 2009 1:42 PM <br /> To: 'Eli Scott' <br /> Subject: RE: Chevron Site 96171 Well Permits(SJC LOP Case# 1784) <br /> Looks like MW-6 and MW-7 are two inch PVC... <br /> MW-9 is unclear. Log shows 8". boring but labels the casing as 4"... <br /> Be prepared to use 10" augers on MW-9' unless you definite) know it's only a 2" <br /> P p 9 � Y Y Y <br /> casing. <br /> -----Original Message----- <br /> From: Eli Scott [mailto:eli_scott@hfa.com] <br /> Sent: Tuesday, August 18, 2009 1 :39 PM <br /> To: Mike Infurna [EH] <br /> Cc: Stephanie McKenna <br /> Subject: Re: Chevron Site 96171 Well Permits (SJC LOP Case# 1784) <br /> Mike, <br /> That is correct. <br /> Thanks! - <br /> Eli <br /> On Aug 18, 2009, at 1 :24 PM, Mike Infurna [EH] wrote: <br /> > I got a chance to look at the plan. <br /> > The way I see it: <br /> > ONSITE permit SR057985/ CASCADE DRILLING MWs 4, 8, 10, 11 get pressure <br /> > grouted. NO less than one foot of grout OVER top of cut off pvc <br /> > casing. <br /> > MWs 6, 7, 9 get over bored to total depth of construction + 1 foot. <br /> > MWs 2, 3, & 5 stay and become property/responsibility of LCERT. <br /> > No MW-1 exists. <br /> > Offsite PERMIT SR058087/ CASCADE DRILLING: <br /> > MW-12, -13, -14 get overbored. <br /> > Verify please. <br />