Laserfiche WebLink
• � 11 <br /> SIERRA. <br /> Table 3 Analytic Results for Ground Water-Volatile Organic Compounds-Chevron Service Station#9-6171, 6633 Pacific Avenue, <br /> Stockton, California <br /> Well Date Analytic Analytic 1,2-DCA 1 1-DCA TCE PCE Other VOCs <br /> ID Sampled Lab Method <-------------------------------------------------ppb---------------------------------------> <br /> MW-1' <br /> MW-2 3/14/91 APPL 8240 <0 5 <0 5 08 42 ND <br /> MW-3 3/14/91 APDL 8240 <0 5 <0 5 <0 5 05 ND' <br /> MW-4 3/14/91 APPL 8240 <0 5 <0 5 <0 5 850 ND" <br /> MW-5 9/5/90 SAL 624 <3 7 <3 <3 ND4 <br /> 11/29/90 SAL 8240 11 <3 <3 4 ND4 <br /> 3/14/91 SAL 8240 28 <3 <3 10 ND4 <br /> 3/14/91 APPL 8240 26 <3 22 92 ND <br /> 6/6/91 SAL 8240 16 <3 <3 11 ND4 <br /> 8/29/91 SAL 8240 15 <3 <3 <3 ND4 <br /> 12/6/91 SAL 8240 68 <3 7 120 ND4 <br /> EXPLANATION ANALYTIC LABORATORIES <br /> TPPH(G) =Total Purgeable Petroleum Hydrocarbons as Gasoline ADPL= Agriculture&Priority Pollutants Laboratories, Inc of Fresno, <br /> B=Benzene California <br /> T=Toluene SAL= Superior Analytical Laboratory of San Francisco, California <br /> E=Ethylbenzene <br /> X=Xylenes NOTES <br /> ppb =Parts per billion <br /> ND =Not detected ' Well has been dry since December 15, 1989 sampling event <br /> 2 Chloroform detected at 1 4 ppb Other VOCs not detected at <br /> ANALYTIC METHODS detection limits of 3 to 20 ppb <br /> 3 Not detected at detection limits of 0 5 to 1 0 ppb <br /> 8240=EPA Method 8240 for VOCs 4 Not detected at detection limits of 3 to 20 ppb <br /> 624 =EPA Method 624 for VOCs <br /> 14604T GWV <br />