• • i <br /> Table 3 Analytical Results for Groundwater-Volatile Organic Compounds -Chevron Service Station/19-6171, 6633 Pacific Avenue, Stockton, California <br /> contmued <br /> EXPLANATION ANALYTICAL LABORATORIES <br /> 1,2-DCA= 1,2-DLchloroethane APPL= Agriculture&Priority Pollutants Laboratories,Inc of Fresno,Cahforma <br /> 1,1-DCA = 1,1-Dichloroethane SAL= Superior Analytical Laboratory of San Francisco,California <br /> TCE =Tnchloroethene GTEL= Groundwater Technology Environmental Laboratories,Inc,of Concord, California <br /> PCE=Tetrachloroethene SEQ = Sequoia Analytical Laboratories of Redwood City,California <br /> B = Benzene Quanterra = Quanterra Environmental Services of West Sacramento,California <br /> T =Toluene <br /> E= Ethylbenzene N(YrF-4 <br /> X =xylenes <br /> VOCs = Volatile Organic Compounds ' Well has been dry since December 15, 1989 sampling event <br /> ppb = Pants per billion 2 Chloroform detected at 1 4 ppb Other VOCs not detected at detection limits of 0 5 to 10 ppb <br /> ND = Not detected i Not detected at detection limits of 0 5 to 10 ppb <br /> ` Not detected at detection limits of 3 to 20 ppb <br /> ANALY77CAL MFPN(1T)S ' BTEX concentrations included on Table 2 Other VOC's not detected at detection limits of 5 to 50 ppb <br /> 6 All other VOC's were non-detectable with detections limits ranging from 40 to 200 ppb <br /> VOC = EPA Method 8240/EPA Method 624& ' All other VOC s were non-detectable with detection lunmts ranging from 100 to 700 ppb <br /> EPA method 8260 ' All other VOC's were non-detectable with detection limits ranging from 22 to 110 ppb <br /> ' Volatile Tentatively Identified Compounds not present at estimated detection limits of 100 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> `0 Volatile Tentatively Identified Compounds not present at estimated detection linuts of 250 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> LL Volatile Tentatively Identified Compounds not present at estimated detection limits of 56 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> L2 Split samples were taken by Levine-Fricke and analyzed by Quanterra Environmental Services of West <br /> Sacramento, for EPA Method 8260 <br /> `i Cis-1,2-Dichloroethene was detected at 16 ppb All other constituents were non-detectable <br /> All other constituents were non-detectable <br /> Cis-1,2-Dichloroelhene was detected at 10 ppb All other constituents were non-detectable <br /> Benzene and toluene were detected at 13 and 12 ppb, respectively All other constituents were non- <br /> detectable <br /> " Toluene was detected at 2 1 ppb All other constituents were non-detectable <br /> is Cis-1,2-Dichloroethane was detected at 19 ppb Chloroform, 1,1,1-Tnchlomethane,benzene,and toluene <br /> were detected at 1 7,7 6, 16,and 1 1 ppb,respectively <br /> Chloroform, 1,1,1-trichloroethane, benzene, and toluene were detected at 3 3, 9 0, 13, and 1 6 ppb, <br /> respectively <br /> 70 Cts-1,2-dichloroethane and 1,1,1,2-tetrachloroethane were detected at 1 9 and l 8 ppb,respectively <br /> 5121VOC 7QM <br /> 2 <br />