Table 3 Analytical Results for Groundwater-Volatile Organic Compounds-Chevron Service Station f19-6171,6633 Pacific Avenue,Stockton, California <br /> (continued) <br /> EXPLANATION ANALYTICAL LABORATORIES <br /> 1,2-DCA= 1,2-Dichloroethane APPL= Agriculture&Priority Pollutants Laboratories, [no of Fresno, California <br /> 1,1-DCA = 1,1-Diehloroethane SAL= Superior Analytical Laboratory of San Francisco,California <br /> TCE =Trichloroethene GTEL= Groundwater Technology Environmental Laboratories,Inc ,of Concord, California <br /> PCE = Tetrachloroethene SEQ = Sequoia Analytical Laboratories of Redwood City,California <br /> B = Benzene <br /> T = Toluene NOTES <br /> E = Ethylbenzene <br /> X = Xylenes 1 Well has been dry since December 15, 1989 sampling event <br /> VOCs = Volatile Organic Compounds = Chloroform detected at 1 4 ppb Other VOCs not detected at detection limns of 0 5 to 1 0 ppb <br /> ppb = Parts per billion ° Not detected at detection limits of 0 5 to 10 ppb <br /> ND = Not detected s Not detected at detection limits of 3 to 20 ppb <br /> ' BTEX concentrations included on Table 2 Other VOC's not detected at detection lirmts of 5 to 50 ppb <br /> ANALYTICAL METHODS s All other VOC's were non-detectable with detections limits ranging from 40 to 200 ppb <br /> ? All other VOC's were non-detectable with detection limits ranging from 100 to 700 ppb <br /> VOC = EPA Method 8240/EPA Method 624& • All other VOC's were non-detectable with detection harts ranging from 22 to 110 ppb <br /> EPA method 8260 ° Volatile Tentatively Identified Compounds not present at estimated detection Itmite of 100 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> 10 Volatile Tentatively Identified Compounds not present at estimated detection limits of 250 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> It Volatile Tentatively Identified Compounds not present at estimated detection limits of 56 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> 13 Split samples were taken by Levine-Fricke and analyzed by Quanterra Environmental Services of West <br /> Sacramento, for EPA Method 9260 <br /> 13 Cts-1,2-Dichloroethene was detected at 1 6 ppb All other constituents were non-detectable <br /> 14 All other constituents were non-detectable <br /> is Cts-1,2-Dichloroethene was detected at 10 ppb All other constituents were non-detectable <br /> is Benzene and toluene were detected at 13 and 1 2 ppb, respectively All other constituents were non- <br /> detectable <br /> 17 Toluene was detected at 2 1 ppb All other constituents were non-detectable <br /> 5121VOC TQM <br /> 2 <br />