Laserfiche WebLink
Table 3 Groundwater Analytical Results - Volatile Organic Compounds - Chevron Service Station #9-6171, 6633 Pacific Avenue, Stockton, CalI orma <br /> (continued) <br /> EXPLANATION ANALYTICAL LABORATORIES <br /> 1,2-DCA = 1,2-Dichloroethane APPL = Agnculture&Priority Pollutants Laboratories,Inc of Fresno,California <br /> I,l-DCA = i,l-Dichloroethane SAL = Superior Analytical Laboratory of San Francisco,California <br /> TCE =Trichloroethene GTEL= Groundwater Technology Environmental Laboratories,Inc,of Concord, California <br /> PCE =Tetrachloroethene SEQ = Sequoia Analytical Laboratories of Redwood City,California <br /> B = Benzene Quanterra = Quanterra Environmental Services of West Sacramento,California <br /> T=Toluene <br /> E = Ethylbenzene NOTF..S <br /> X = Xylenes <br /> VOCs=Volatile Organic Compounds ` Well has been dry since December 15, 1989 sampling event <br /> ppb= Pani per billion ' Chloroform detected at 1 4 ppb Other VOCs not detected at detection lututs of 0 5 to 10 ppb <br /> ND = Not detected 3 Not detected at detection limits of 0 5 to 1 0 ppb <br /> ' Not detected at detection limits of 3 to 20 ppb <br /> ANAT.YTICAT METHOD S BTEX concentrations included on Table 2 Other VOC's not detected at detection linuts of 5 to 50 ppb <br /> All other VOC's were non-detectable with detections limits ranging from 40 to 200 ppb <br /> VOC =EPA Method 8240/EPA Method 624& ' All other VOC's were non-detectable with detection limits ranging from 100 to 700 ppb <br /> EPA method 8260 ' All other VOC's were non-detectable with detection limits ranging from 22 to 110 ppb <br /> 9 Volatile Tentatively Identified Compounds not present at estimated detection limits of 100 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> 1° Volatile Tentatively Identified Compounds not present at estimated detection limits of 250 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> " Volatile Tentatively Identified Compounds not present at estimated detection lints of 56 ppb Positive <br /> identification or specification between isomers cannot be made without retention time standards <br /> L2 identification <br /> samples taken by Levine-Fncke-Recon,analyzed by Quanterra Environmental Services of West <br /> Sacramento Analytical results supplied by Levine-Fricke-Recon <br /> 13Cis-1,2-Dichloroethene was detected at 1 6 ppb All other constituents were non-detectable <br /> All other constituents were non-detectable <br /> 'S Cts-1,2-Dichloroethene was detected at 1 0 ppb All other constituents were non-detectable <br /> 16 Benzene and toluene were detected at 1 3 and 1 2 ppb, respectively All other constituents were non- <br /> detectable <br /> " Toluene was detected at 2 1 ppb All other constituents were non-detectable <br /> Cis-1,2-Dichloroethane was detected at 1 9 ppb Chloroform, 1,1,1-Trichloroethane,benzene,and toluene <br /> were detected at 1 7,7 6 l 6,and 1 1 ppb,respectively <br /> 'p Chloroform, 1,1,1-tnchloroethane, benzene, and toluene were detected at 3 3, 90, l 3, and 1 6 ppb, <br /> respectively <br /> 30 Cts-1,2-dlchloroethane and 1,1,1,2-tetrachloroethane were detected at 19 and 18 ppb,respectively <br /> 5121VOC TQM <br /> 2 <br />