My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006371
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2900 - Site Mitigation Program
>
PR0528433
>
ARCHIVED REPORTS_XR0006371
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2020 1:12:08 PM
Creation date
4/3/2020 4:45:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006371
RECORD_ID
PR0528433
PE
2957
FACILITY_ID
FA0019174
FACILITY_NAME
CHEVRON SERVICE STATION 9-6171
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
09741048
CURRENT_STATUS
02
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\sballwahn
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
l <br /> Lancaster Laboratories ' <br /> ti 2425NewH*RlndPike eLancaster PA17601 Explanation of Symbols and Abbreviations <br /> I The following defines common symbols and abbreviations used in reporting technical data <br /> `r s <br /> N D none detected r y BMQL Below Minimum Quantitation Level <br /> TNTC Too Numerous To Count I MPN Most Pi=obable Number �. <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhoslcm micromhoslcm - NTU nephelometric turbidity units <br /> C—degrees Celsius —F—degrees Fahrenheit <br /> meq milliequivalents Ib pound(s) , t <br /> g gram(s) kg kilogram(s) <br /> Ug microgram(s) _ mg milligram(s) <br /> ml milliliter(s) ` I - liter(s) -_ " ' <br /> m3 cubic meter(s) ull microliter(s) <br /> less than-The number following the sign is the limit of quantitation, the smallest amount of analyte which can be <br /> -reliably determined using this specific test <br /> > greater than <br /> J estimated value–The result falls within the Method Detection Limit(MDL)and Limit of Quantitation (LOQ) <br /> PPM parts per million-One ppm is equivalent to one milligram per kilogram (mg/kg), or one gram per million grams For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a <br /> weight very close to a kilogram For gases or vapors, one ppm is equivalent to one microliter of gas per liter of gas <br /> ppb parts per billion " <br /> Dry weight Results printed under this heading have been adjusted for moisture content -This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture All other results are reported <br /> on an as-received basis <br /> U S EPA CLP Data Qualifiers <br /> Organic Qualifiers Inorganic Qualifiers <br /> A TIC is a possible aldol-condensation product B Value is<CRDL, but>_IDL r� <br /> B Analyte was also detected in the blank E Estimated due to interference <br /> C Pesticide result confirmed by GC/MS M Duplicate infection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> _E_ _ Concentration exce_e_ds the calibration range of---S r Method of standard additions (MSA) used <br /> the instrument T for calculation <br /> N _ _Presumptive_evidence_o_f a compound (TICs only), _U_ Compound was not detected _ <br /> P Concentration difference between primary and W Post digestion spike out of control limits <br /> confirmation columns >25%_ _ __ _ Duplicate analysis not_within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0 995 <br /> X,Y,Z Defined in case narrative <br /> Analytical test results for methods listed on the laboratories' accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis <br /> Measurement uncertainty values, as applicable, are available upon request <br /> Tests results relate only to the sample tested Clients should be aware that a critical step in a chemical or microbiological <br /> I' analysis is the collection of the sample Unless the sample analyzed is truly representative of the bulk of material involved, the <br /> test results will be meaningless If you have questions regarding the proper techniques of collecting samples, please contact <br /> us We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> --.—staff This report shall not-be reproduced except in full,-without the written approval-of the laboratory <br /> WARRANTY AND LIMITS OF LIABILITY- In accepting analytical work,we warrant the accuracy of test results for the sample as submitted <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br /> IMPLIED WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF (A)THE NEGLIGENCE (EITHER SOLE OR CONCURRENT) OF LANCASTER <br /> LABORATORIES AND (B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OF SUCH <br /> DAMAGES We accept no legal responsibility for the purposes for which the client uses the test results No purchase order or other order 49 <br /> for work shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions of <br /> Lancaster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by client <br /> 376801 <br /> l <br />
The URL can be used to link to this page
Your browser does not support the video tag.