Laserfiche WebLink
Jimco Truck Plaza - 2 - Y 10 November 2009 <br /> 1022 East Frontage Road ' U <br /> Ripon, San Joaquin County j <br /> tv <br /> Comments: or <br /> The installation of nine monitoringwells indicated in CAP Figure 7 for the investigation work plan is <br /> approved. Please provide a detailed schedule for implementation of the investigation.work plan in an <br /> email-to me by 11 December 2009, anc o oceed immediately with well permits and access . <br /> agreements. <br /> The CAP recommendation for submitting a FP extraction system remedial work plan is not approved at j <br /> this time. In future monitoring events., if FP is encountered in monitoring wells, you will measure the <br /> thickness of FP, attempt to hand bail each well containing FP; and properly contain and dispose the <br /> FP. You will also document the work in an email to me within one week of FP discovery and provide. <br /> updates each following week, describe the FP removal action and include a table of dates when FP <br /> was encountered, measured thickness of FP, time of recovery, and volume of FP removed. After one <br /> month of hand bailing, a determination will be made whether a mechanical FP extraction system is <br /> more cost effective than hand bailing, and a remedial action work plan for FP will be requested. <br /> Further direction on FP removal may be included in subsequent responses to the above requested <br /> emails. <br /> s . <br /> j. <br /> While sodium persulfate and hydrogen peroxide are listed as examples of ISCO oxidants("such as...") <br /> in the CAP, the text does not specify which oxidant(s)would be used during the bench scale testing <br /> and pilotstudy. The CAP also says ISCO injections will occur quarterly for two years, and CRA will <br /> conduct performance monitoring of ISCO in the same injection wells. A recommendation designating <br /> specific oxidant(s)would be beneficial prior to submittal of the bench scale testing and the pilot study <br /> work plan, to help design the monitoring program used to evaluate potential effects of the injections on <br /> the aquifer for the injection permit. As noted in the CAP, all injection of substances into the aquifer <br /> require an injection permit from this office, specifically Order No. R5-2008-0149, Waste Discharge <br /> Requirements, General Order for In-Situ Groundwater Remediation at Sites with.Volatile Organic <br /> Compounds, Nitrogen Compounds, Perchlorate, Pesticides, Semi-Volatile Compounds, Hexavalent <br /> Chromium and/or Petroleum Hydrocarbons, which may be downloaded from the Internet at <br /> http://www.waterboards.ca.gov/centralvalleviboard decisions/adopted orders/general. orders/r5-2008- <br /> 0149.pdf.'By`30 December,2009,provide a resporise specifying_the oxidant(s) proposed for ISCO.. <br /> Also, provide a technical justification for the`prbposed use of combined injection/performance wells for <br /> ISCO, eAq t1''fdltatrtel'ly frequency of the ISCO injections for two.years. 1f desired, you may revise the <br /> CAP cost of the ISCO remediation to show a one-time full scale ISCO injection with temporary injection <br /> points and use of the existing/approved proposed monitoring wells as performance/compliance points <br /> for the injection permit. Upon review of the information, we will provide a decision for submittal of an <br /> ISCO BST/PS work plan. <br /> Note that AGTs releases are not a part of the USTs cleanup program, and that we (UST program) are <br /> discussing this case with the AGT program staff, with the objective of integrating the approach for the <br /> two releases under one remedial action as the most cost effective means for reaching water quality <br /> goals. Further direction will follow this inter-program discussion. If you have any questions, please <br /> co tact me at (916) 464-461 or via e-mail at jbarton@waterboards.ca.gov. <br /> James L.L. Barton,'P. G. <br /> Engineering Geologist <br /> cc: Mr. Robert L'Heureux, SWRCB UST Cleanup Fund, Sacramento f <br /> Ms. Margaret Lagorio, San Joaquin Co, 600 E. Main St., Stockton 95202 <br /> Mr. Roil Scheele, Conestoga-Rovers Assoc., 5900 Hollis St., Ste. A, Emeryville,.94608 <br /> i <br /> I <br />