,E <br /> 7.0 TOPOGRAPHIC SURVEY 6 MAPPING - -' <br /> The AE shall provide topographic (topo) maps of the project areas as shown on <br /> Figure 1 and Figure 2. The topo maps shall include a 100 foot square (100 FT <br /> by 100 FT) at the proposed location of the treatment facility, and proposed <br /> holding pond, and a 50 foot wide strip survey of the water transmission lines <br /> (including all of the wells) . The surveys shall be provided at a scale of one <br /> inch = 30 feet and show one foot contours with each five foot contour being <br /> identified. The topo maps and all coordinates shall be referenced to the <br /> North American D.a-_um of 1983 (NAD83) ; and all elevations shall be referenced <br /> to the North American Vertical Datum of 1988 (NAVD88) . The final drafted topo <br /> map shall be on a polyester drawing film (mylar) which is 30" x 42" (standard <br /> "F" size drawing) . <br /> 7. 1 All surface features within the area to be surveyed shall be shown <br /> and identified on the 1 inch = 30 feet topo maps. In addition, these features <br /> shall be located by sufficient distance ties and labeled on the topo sheets to <br /> permit accurate scaling and identification. The phrase "surface features" is <br /> intended to include, but is not necessarily limited to, the following existing <br /> features: <br /> 7.1.1 Power lines and communication lines (underground as well as above <br /> ground) , street light poles, guy wires, vaults (including handholes and <br /> manholes) , transformers and substations. Indicate the type and number of each <br /> power pole, the number of wires, and locate the intersection of all guy wires <br /> with the natural ground. <br /> 7.1.2 Sanitary and industrial sewer manholes and all storm drainage <br /> structures, such as culverts, headwalls, inlets, cleanouts, and manholes. Al- <br /> ways obtain an elevation at the flow line at the bottom of all the pipes con- <br /> nected to a manhole or inlet (invert elevations) . Clearly identify the size <br /> and type of each pipe. Obtain the pipe invert elevation up and downstream of <br /> all manholes and inlets even if beyond the limits of the required topo. <br /> Provide sketches where needed for detail and clarity. <br /> 7.1.3 Water, gas, and other above or below ground pressure pipes. Lo- <br /> cate all fire hydrants, hose bibs, valve meters, regulators, and so forth, <br /> within the limits of the area to be surveyed. Include all information on the <br /> location and the size of each pressure pipe on the topo map. Use sketched in- <br /> serts where needed for detail and clarity. <br /> AA-19 <br />