Laserfiche WebLink
� D � F <br /> 6 H J <br /> S <br /> Architecture <br /> Planning & <br /> Design <br /> 9714 Dublin Ct <br /> Stockton, CA 95209 <br /> TENANT IMPROVEMENT ,j P.209.331 .6185 <br /> tpjplanning@gmai4.com <br /> Thl5 drawing 15 an instrument of service <br /> only, and is , and shall remain, the property <br /> of TPJ Architecture � Planning Co. No <br /> reproduction or other use shall be made <br /> by any person or firm without written <br /> permission of the architect. Unauthorized <br /> use shall void the profe551onal seal and <br /> 519nature hereon and no profe551onol <br /> responsibility w111 remain. <br /> Written dlmen5ion5 on thl5 drawing Shall <br /> have precedence over any Scaled <br /> ■ dimen5ion. Do not Scale this drawing for <br /> accurate dimen5ion5, and notify the <br /> 1" FOR , TOP FLIGHT BAR & GRILi <br /> architect of any d15crepancle5. <br /> @ TPJ PLANNING CO. 2019 <br /> i <br /> ORT <br /> N METROPOLITAN A RP� <br /> STOCKTO <br /> AIRPORT WAY , STOCKTON CA , 95206 <br /> i <br /> i <br /> i <br /> i <br /> m <br /> Q o <br /> i, � oa � N <br /> LO <br /> Uj <br /> P RoJC CT SHEET NUMBER SHEET NAME <br /> C Q <br /> AG ASPHALTIC CONCRETE INT INTERCOM I. ALL WORK S AND TRADE ARCHITECTURAL <br /> SHALL COMPLY WITH LATEST APPLICABLE GODE <br /> STANDARDS HHIGH GOVERN EACH PHASE OF HORK, INGLUDING BUT NOT <br /> A <br /> ZONINO: GL. GOMMERGIAL A-0 TITLE SHEET <br /> GG AGGREGATE INTR INTERIOR LIMITED TO: <br /> AIG AIR CONDITIONER JT JOINT 2016 CALIFORNIA BUILDING CODE 2016 CALIFORNIA MECHANICAL CODE CONSTRUCTION TYPE: VB A-I ENLARGED EXITING PLAN <br /> rt _j <br /> LB LAGBOLT 2016 CALIFORNIA PLUMBING GODE 2016 CALIFORNIA ELECTRICAL GODS s <br /> AL ALUMINUM .^ �_ _ � _ _ . <br /> .. A-2 AGGESSIBILITY a FLOOR PLAN 7 <br /> LAV LAVATORY 2016 CALIFORNIA ENERGY ST. 2016 GALIFORNIA GREEN GORE u- Z <br /> AB ANCHOR BOLT STORIES : I 9a _.._r _.. _.. <br /> AT LT LIGHT 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT MATERIALS, �' + A3 INTERIOR ELEVATIONS DI=TAILS o 0 <br /> m. <br /> ® E=S AND A-4 GREEN BUILDING STANDARDS _ <br /> ABV ABOVE MAX MAXIMUM LABOR, INSTALLATION, ETC., CONFORMS TO THE GOD ALLOWABLE AREA: G,000 5Q. FT. <br /> REQUIREMENTS OF LOCAL GOVERNING AGENCIES. o <br /> MIN MINIMUM <br /> J BLK'6 BLOCKING A-S GREEN BUILDING STANDARDS �/ <br /> Q 3. ALL WORK SHALL GOMPLY HITH LOCAL ORDINANCES AND STATE LAWS. OCCUPANCY TYPE: B <br /> BD BOARD NIG NOT IN CONTRACT <br /> U � .ti` � A-6 GREEN BUILDING STANDARDS <br /> 4. ALL CONSTRUCTION SHALL CONFORM TO GURRENT TITLE 24, CALIFORNIA <br /> BUR BUILT UP ROOFING NTS NOT TO SCALE PROJECT: TENANT IMPROVEMENT " <br /> GB GATGH BASIN O/ OVER <br /> ADMINISTRATIVE CODE ACCESSIBILITY REQUIREMENTS. P-I PLUMBING LEGEND AND NOTES <br /> I-' �. ALL PUBLIC IMPROVEMENTS SHALL BE MADE IN AGGORDANGE WITH THE SPRINKLER SYSTEM: BUILDING 15 SPRINKLERED, NOT GHANGE NEEDED p-2 PLUMBING AND ELECTRICAL PLAN `— <br /> CONCRETE GOLD JOINT OBS OBSCURE <br /> CD p, GCJ LATEST ADOPTED GOUNTY STANDARDS. <br /> W CJ GOLD JOINT OG ON GENTER <br /> 6. ALL MECHANICAL, PLUMBING, AND ELEGTRIGAL EQUIPMENT SHALL BE FIRE ALARM: DEFERRED APPROVAL u- <br /> Z GFCI GONTRAGTOR FURNISHED OFGI ONNER FURNISHED ANCHORED AND 5E=15MICALLY BRAGED PER CODE. <br /> W CONTRACTOR INSTALLED CONTRACTOR INSTALLED SCONE: TENANT IMPROVEMENT OF WAITING AREA, THE USE IS TO BE ANcc f <br /> f. DIMENSIONS ON HORKINCo DRAWINGS GOVERN. DO NOT SCALE DRAWINGS BAR AREA INGLUDING PUBLIC SEATING AREA, SERVERY COUNTER WITH i <br /> LL GLG CEILING OF01 OWNER FURNISHED <br /> OHNER INSTALLED 8. ALL TYPICAL DETAILS SHALL APPLY UNLESS NOTED OTHERHISE. THE 3-- GOMPARTMENT SINK, GASH REGISTER AND (E) STORAGE ROOM. NO <br /> O COLUMN T FOR TYPICAL CONDITIONS. THE GOOKING HILL TAKE PLACE. HVAG IS EXISTING IN <br /> NO CHANGES TED <br /> W G L DETAILS REFLECT THE DESIGN INTENT <br /> _ <br /> GONG CONCRETE D OXYGEN (HTO LOCATIONS REQUIRED. GEILING I5 (E) WITH NO CHANGES, AREA IS <br /> 10 <br /> OUTLET) CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND SHALL INCLUDE, - <br /> p IN HIS SCOPE, THE COST FOR COMPLETE FINISHED INSTALLATION, <br /> GMU CONCRETE MASONRY UNIT OH OVERHEAD SPRINKLERED WITH NO GHANGI=S REQUIRED. � <br /> INCLUDING ANOMALIES, OF ALL TRADES. <br /> Q GONT CONTINUOUS OR CONTINUE PVMT PAVI=MI=NT <br /> DET DETAIL PL PLATE g. ALL CONTRACTORS SHALL THOROUGHLY REVIEW CONTRACT DOCUMENTS BUILDING AREA: TOTAL EXISTING BUILDING AREA 180 S.F. <br /> 0 <br /> W AND SITE GONDITIONS PRIOR TO PROGEEIDING HITH NORK. PRIOR TO r <br /> Ir DIAG <br /> DIAGONAL PLN PLAN BIDDING, CONTRACTOR SHALL NOTIFY THE OWNER AND ARGHITEGT OF <br /> W DS DOWN SPOUT PLYNO PLYNOOD ANY CONDITIONS HHIGH ARE NOT COVERED IN THE CONTRACT SITE AREA: Ic16,020 S.F. TOTAL REVISIONS <br /> p DOCUMENTS. DURING CONSTRUCTION, CONTRACTORS SHALL NOTEFY THE <br /> DHGS DRAWIN65 PT PRESSURE TREATED OHNER AND SEEK GLARIFIGATION IF ANY DISCREPANCIES ARE FOUND. <br /> - �. <br /> La <br /> N_ DIA DIAMETER RAD RADIUSlu. NU DRAWING INDEX <br /> cn EJ EXPANSION JDINT COVER RD ROOF DRAIN DONE WITH UNAPPROVED MATERIALS AND EQUIPMENT IS AT THE PROJECT DATA <br /> ROJ ECT LOCATION <br /> cr W ELECT ELECTRICAL <br /> RFG ROOFING CONTRAGTOR'S RISK. <br /> = ELEV ELEVATION RMROOM 11. CONSTRUCTION MATERIALS STORED ON THE SITE SHALL BE PROPERLY <br /> STACKED AND PROTECTED SD AS TO IN THIS REGARD MAY BE CAUSE I I { 1 <br /> r <br /> O EQ EQUAL SGH 5GHE PULE DETERIORATION UNTIL USED, <br /> FAILURE PROJECT <br /> FOR REJEGTION OF MATERIAL AND/OR HORK. X SECTION NUMBER <br /> V I � <br /> E ELECTRICAL WALL SH SINGLE HUNG HINDOW i <br /> . s <br /> >_ XX SHEET NUMBER : _ . a. i r <br /> Z REGEPTAGLE 5HT SHEET 12. FINISHES AND CON5TRUGTION SHALL BE PROTECTED BY THE GONTRAGTOR <br /> FROM POTENTIAL DAMAGE CAUSED BY GONSTRUGTION ACTIVITY. <br /> (E) EXISTING SEM SIMILAR <br /> � DAMAGE TO FINISHES OR CONSTRUCTION CAUSED IN THIS MANNER SHALL VIEW DIRECTION <br /> d EXH EXHAUST SPEG SPECIFICATION BE REPAIRED OR REPLACED (OHNER5 $ ARCHITECTS DECISION) BY <br /> EXT EXTERIOR SPR SPRINKLER GONTRAGTOR HITH IDENTICAL MATERIAL AND/OR FINISHES. <br /> A DOOR TYPES ;a# TITLE SHEET <br /> FOS FAGE OF STUD SQ SQUARE <br /> � 13. ALL CONTRACTORS SHALL REMOVE TRASH AND DEBRIS RESULTING FROM � <br /> FLUOR FLUORESCENT STD STANDARD THEIR NORK ON A DAILY BASIS. PROJECT SITE SHALL BE MAINTAINED IN <br /> A GLEAN AND ORDERLY CONDITION. <br /> FIN FINISHED) STOR STORAGE �A����� jc <br /> N <br /> �l V!J#NDOW TYPE .. <br /> FLR FLOOR SY5 SYSTEM 14. IN ADDITION TO TH05E SHOWN ON DRAWINGS, PROVIDE AND LOCATE <br /> ACCESS DOORS OR PANELS IN CEILING AND WALL CONSTRUCTION AS <br /> W FD FLOOR DRAIN TEL TELEPHONE RE UIRED FOR MEGHANIGAL, PLUMBING, AND ELECTRICAL NORK. ROOM <br /> Z FTG FOOTING THK THICK Q ROOM NUMBER <br /> FOUNDATION TaO TONGUE 4 GROOVE <br /> 15. PROVIDE BACKING FOR ALL EQUIPMI=NT AND AGGESSORIES. <br /> nC FND a <br /> (REFERENCE ONLY) , ° Data <br /> �: �� . . y, �■� 2120119 <br /> (L D VERIFY "AS-BUILT" CONDITIONS AND NOTIFY THE <br /> GA GAUGE TYP TYPICAL 16. GONTRAGTOR TO FIEL ' <br /> W ARGHITEGT IF THEY VARY SUBSTANTIALLY FROM THOSE SHONN. DETAIL NUMBER ° k Scale <br /> rQ <br /> &ALV GALVANIZED UON UNLESS OTHERHISE NOTED <br /> NS ARE FOR GENERAL CONSTRUCTION PURPOSES ONLY. THEY X SHEET NUMBER 1�.`� � � - AS SHOWN <br /> GL GLASS OR GLAZING VGT VINYL GOMP051TIONAL TILE 1-1. THESE PLA s " F <br /> � ARE NOT EXHAUSTIVE=LY DETAILED NOR FULLY SPECIFIED, IT IS THE VIEW DIRECTION �� '�,' <br /> I Drawn <br /> GYP BD GYPSUM DRY WALL YAG VACUUM RESPONSIBILITY OF THE GONTRAGTOR/ OWNER TO SELECT, VERIFY, # 1 6E TJ <br /> Z RESOLVE AND INSTALL ALL MATERIALS AND EQUIPMENT. <br /> H/G, HG HANDICAPPED V VAGUUM (HALL OUTLET) ELEVATION LETTER JOb <br /> Q HDR HEADER VB VIEN BOX 18. THE ARCHITECT HILL NOT BE OBSERVING THE CONSTRUCTION OF THIS # e. <br /> W X SHEET NUMBER f 0139 <br /> HVAC HEATING / VENTILATION / AIR NC WATER CLOSET PROJECT. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE QUALITY � <br /> CONTROL AND GONSTRUGTION STANDARDS FOR THIS PROJECT. ALL # Sheet <br /> W CONDITIONING HD WOOD QUE5VON5 AND CLARIFICATIONS SHALL BE BROUGHT TO THE ATTENTION <br /> 3�: <br /> HT HEIGHT W/0 WITHOUT OF THE OHNER. <br /> Z HORIZ HORIZONTAL NP WEATHER OR HATER PROOF 11. COORDINATE ALL NORK AND GONSTRUGTION SCHEDULING HITH OHNE~R. X'-X" ELEVATION HEIGHT <br /> _ <br /> 2� HB HOSE BIBB 20.ALL EXISTING CONDITIONS NOT SHOHN OR INDICATED ON THFSE PLANS AO <br /> my. <br /> < ARE TO REMAIN UNCHANGED, <br /> ABBREVIATIONS GENERAL NOTES SYMBOLS <br /> VICINITY MAP AREA OF WORK <br /> F- <br />