Laserfiche WebLink
Not Shown Does nc <br /> REVIEW CHECK LIST Submitted Inccap et Conforn <br /> E. STCRM SEWER REVIEW: <br /> 1. Position of sewer with dimensions to street right-o=-way <br /> lines <br /> 2. Lpanaths of sewer in feet between manholes <br /> 3, Types and size of sewer lines <br /> 4. Design calculations for storm sewer (piping system with <br /> lan showing tributary area, pond etc. ) <br /> D. Profile of proposed design rade on centerline or street <br /> 6. Location of manholes and catch basins, showing flowline <br /> elevations at manholes (Lat. connected to M-H not into <br /> trunk lines) _ <br /> 7. MH spacing (500' max For 24" diameter or smaller, and <br /> 600' max. for > 24" diameter, gutter run to a single SDI <br /> (700' max. ) <br /> 8. Profiles of pioe showing percent slope petween manholes <br /> 9. Tyical manhole details <br /> 10. Typical storm drain inlet details (lataral 12" diameter <br /> min. ) <br /> 11. P=j.-ng plant system (including electrical details, pump <br /> house, fence, caved access, unpaved shall be sterilized) <br /> 12. Trash rack (either in last NN afore station or an angle ) <br /> rack in station) <br /> 13. Drainage ponds (volume required and capacity, bottom <br /> elevation, side slopes, fence with 18' double gate, <br /> around water elevation) <br /> 14. Provision for terminal drainage (within one mile of a <br /> terminal drainage facility) <br /> 15. Outfall structure <br /> 16. Trench detail <br /> 17 . Multi-pump system provided <br /> 18. Manufacture`r's specifications and data on pumps and <br /> ecui cxrnn t <br /> 19. Borina recuirement for existing street or road <br /> 20. C-cerator's manual for pumps, eauioment, etc. <br /> I <br /> R yjzkZSCS <br /> H PS-RCL5 (9/89) <br />