Laserfiche WebLink
BUILDIN <br /> G AND <br /> SAFETY <br /> CONSTRUCTION <br /> 1. Entrance door to be self-closing. <br /> 2. All compressor units shall be separated from food preparation and food storage areas while being made accessible from the outside. <br /> 3. All doors should close tightly and all openings in or around pipes, floors and walls are to be tightly sealed and secured from rodents. <br /> 4. Sinks are to be constructed of stainless steel metal with mixed hot/cold faucets. Must include stainless steel drain boards with a slope 0.125(1!8" ) per foot. <br /> 4.1 All food contact surfaces, counter tops, food compartments, walls and ceilings are stainless steel 304 #4 grade. <br /> 5. Must include a single service soap and towel dispenser. <br /> 6. Floor surface is to be impervious, smooth and easy to clean. Should provide employee safety from slipping. <br /> 7. All equipment to be easily cleanable without channels or crevices. there must not be exposed threads, nuts, or rivets that may interfere with proper cleaning of equipment. <br /> insulation below griddle is to be completely covered and unexposed. <br /> 8. All construction joints and weld seams to be sealed, smooth, and cleanable. <br /> 9. Floor mounted equipment to be sealed to the floor or elevated at least 6" off the floor on clean, round, metal legs. <br /> 10. All equipment to be sealed together or spaced a minimum of 4" apart from each other. <br /> 11. An accurate thermometer is to be provided in all refrigeration units. <br /> 12. All light bulbs and tubes to be enclosed in plastic. <br /> 13. All serving openings are to be equipped with self-closing solid windows or screens. <br /> 14. Water heater shall be capable of providing hot water to the sink at a minimum of 6 gallons' capacity. An instantaneous water heater should be capable of producing water <br /> at 120 F. <br /> 15. Floor covering material shall extend up the sides of the walls a minimum of 4". <br /> 16. Wall and ceiling surface should be durable, impervious, smooth and easily cleanable. <br /> 17. Each service window opening shall be limited to 216 SQ. inches. a minimum distance of 18" must be maintained between each opening. <br /> shormoz@calcentraLus <br /> 18. The minimum ceiling height is 74" high. (209) 549-4549 EXTA15 <br /> UNLESS OTHERWISE SPECIFIED: PROJECT NO. <br /> 19. Aisles are to be a minimum of 30" wide and 76" in height. DIMENSIONSARE ININCHES TOLERANCES: CCCL BTFP-20922021216 <br /> DEGURR ALL SHARP EDGES TO 0.021 - <br /> FRACTIONAL±1/32 .. <br /> ANGULAR:MACH±1° - - DESCRIPTION: <br /> TWO PLACE DECIMAL ±0.06 <br /> 20. Walls and ceiling are to have a stainless steel metal finish. THREE PLACE DECIMAL 20'BOX TRUCK,FLOOR PLAN <br /> ±0.03 <br /> PROPRIETARY AND CONFIDENTIAL <br /> THE INFORMATION CONTAINED IN THIS PROJECT: <br /> 21. DRAWING IS THE SOLE PROPERTY OF CAL ADDRESS: 20922021216 <br /> Floor finish shall be of diamond plate aluminum. CENTRAL CATERING TRAILERS CO. ANY 3511 FINCH Rd Ste A, <br /> REPRODUCTION IN PART OR AS A WHOLE <br /> WITHOUT THE WRITTEN PERMISSION OF CAL MODESTO,CA 95357 ENGINEER: <br /> CENTRAL CATERING TRAILERS CO IS PHONE:(209)549.1549 <br /> 22. Ceiling vent screen mesh shall be a.minimum of 16- Mesh per square inch. <br /> PROHIBITED. sharmazfcalcenlraLas "S""""°NY <br /> CLIENT: WEIGHT: DATE: REV. <br /> YESENIA MORALES N/A 2/13/2019 B <br /> 23. The vertical distance between the lip of hood and the cooking surface shall not exceed four feet. STATUS: RELASEU ooNOT SCALE SIZE <br /> DRAWING SHEET2 OF <br /> 26 D SCALE:1:1 <br />